User Guide
21
7
Installation of Fireplace
CAUTION! Risk of Cuts/Abrasions. Wear protective
gloves and safety glasses during installation. Sheet metal
edges are sharp.
A. Things to Consider
• Location(s)ofoutsideairkit(s)
• Gaslinepiping
B. Position the Fireplace
• Placethereplaceonacontinuousatsurface.
• FollowframinginstructionsinSection6.
WARNING! Risk of Fire! Prevent contact with sagging,
loose insulation.
• DO NOT install against vapor barriers or exposed
insulation.
• Secure insulation and vapor barriers.
• Provide minimum air space clearances at the sides
and back of the replace assembly as outlined in
Section 6.
Raised Platform
Floor
2 in.
(51 mm)
1 in. (25 mm) min.
overlap
2 in.
(51 mm)
Top piece must overlap
bottom piece
Metal strips are placed 2 in. (51 mm)
under the front of the fireplace and must
extend beyond the front and sides of
fireplace opening by 2 in. (51 mm).
1 in. (25 mm) overlap
Minimum
Figure 7.1 Position the Protective Metal Hearth Strips
C. Place Protective Metal Hearth Strips
WARNING! Risk of Fire! Metal hearth strips MUST be
installed. DO NOT cover metal strips with combustible
materials. Sparks or embers may ignite ooring.
• RefertoFigures7.1and7.2.
• Locatethetwometalhearthstripsmeasuringapproximately
26 in. x 4 in. (660 mm x 102 mm) included with this
replace.
• Slideeachmetalstrip2in.(51mm)underfrontedgeof
replace.
• Overlapstripsinthemiddleofreplaceopeningby1in
(25mm)minimum..
• Metalstripsmustextendbeyondthefrontandsidesofthe
replaceopeningbyatleast2in.(51mm).
• Protectthefrontofaplatformelevatedabovethehearth
extensionwith metalstrips(notincludedwithreplace)
per Figure 7.2. See Section 12 for hearth extension
instructions.
D. Level Fireplace
• Levelreplaceside-to-sideandfront-to-back.
• Shimwithnon-combustiblematerialasnecessary.
• Secure replace to framing with nailing anges with a
minimumoftwofastenerspernailingange.
• Checkreplaceopeningforsquaretoensurepropertof
glassdoors.Measurediagonalsofreplaceopeningto
makesuretheyareequal.
Figure 7.2 Protect the Front of an Elevated Platform
Heatilator•BirminghamBIR42•4059-308RevJ•1/11