Owner Manual

2
204058-01
Move ON-TIME Switch
to 1, 5, or 20 minutes
Mode Switching Summary
Flip light switch
off for one second
then back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
DualBrite
®
Timer
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). Selecting OFF disables
this feature. The motion sensing features will continue
to work as described in this manual. If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5, or
20 minutes) then returns to dim mode.
INSTALLATION
Foreavemountonly:
1. Swing the sensor head towards the clamp screw
joint.
If the sensor pops out of the ball joint, loosen the
clamp screw and push the sensor back into the ball
joint. Tighten the clamp screw when done.
2. Then rotate the sensor head clockwise 180° so the
controls face down.
Controls
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operationandtoavoidtheriskofelectricalshock.
Controls
Controls
Clamp Screw
CAUTION: To Avoid Fire Or Burn Hazards:
•Allowxturetocoolbeforetouching.Thebulband
the fixture operate at high temperatures.
• Keep xtureatleast2"(51 mm)fromcombustible
materials. Do not aim at objects closer than 3' (1 m).
• UseonlyT4100W(max.),G8tungstenhalogen
bi-pin 120 VAC bulbs.
CAUTION: Keep the sensor at least 2" (51 mm)
away from the bulbs.
For easy installation, select an existing light operated
by a wall switch for replacement. IMPORTANT: Do NOT
use with dimmers or timers.
For best performance, mount the fixture about 8 feet
(2.4m)abovetheground.NOTE: If fixture is mounted
higher than 8 feet (2.4 m), aiming the sensor down will
reducecoveragedistance.