Installation Instructions
2
204056-02
ON-TIME
TEST 1 5 10
SENS
MIN MAX
TEST AND ADJUSTMENT
1. Turn on the circuit breaker and light switch.
In the test position shown above, the light will turn
on for 5 seconds each time motion is detected dur-
ing both daylight and darkness.
ON-TIME SENS
Bottom of Sensor
NOTE: Sensor has a 1
1
/
2
minute calibration period
before it will detect motion. When first turned
on, wait 1
1
/
2
minutes.
INSTALLATION
For best performance, mount the fixture about 7 feet
(2.1 m) above the ground.
1. Turn the power to the lighting circuit off at the
fuse or circuit breaker box.
2. Remove the existing light fixture.
3. Install the mounting strap
into the junction box. Ori-
entation of the strap may
be different.
4. Strip about 5/8 in. (15 mm)
insulation off of the existing
junction box wiring.
5. Connect the white (neutral) junction box wire to the
white Entryway Light wire. Twist the wires together
and secure with a wire connector.
6. Connect the green or
bare (ground) mounting
strap wire to a grounded
wire or to a grounded
metal box.
7. Connect the black
(hot) junction box
wire to the black En-
tryway Light wire.
8. Install the mounting stem into the strap so
that it extends out about 3/4 in. (19 mm).
9. Install the fixture over
the mounting stem.
10. Install and tighten the
mounting stem nut.
Holding Screw
for Globe or Jar
11. Caulk the back edge of the light and mounting
surface with silicone weather sealant.
12. Install a 60 Watt maximum light bulb into the lamp
holder. Do not overtighten. Higher wattages will
void warranty.
13. Loosen the front holding screw so the globe or jar
cover can be installed. Secure by tightening the
screw. Do not overtighten.
2. For aiming, turn the SENSITIVITY (SENS) control
to the mid position and the ON-TIME control to the
TEST position.