Installation Instructions
5
204069-01
TESTING AND ADJUSTMENTS
1. Turn on the circuit breaker and light switch.
Note:Sensorhasa1
1
/
2
minutewarmupperiodbefore
itwilldetectmotion.Whenrstturnedonwait1
1
/
2
minutes.
2. Set:
ON-TIMEswitchtoTEST
SENSITIVITYdialtoMidway
3. Walkthroughthecoverageareanotingwhereyouare
whenthelightsturnon.InTESTmode,lightwill
stayonfor5secondsaftersensingmotionandthen
turno.
4. AdjusttheSENSITIVITYtoincreaseordecrease
therangeasneeded.Toomuchsensitivitymaycause
falsetriggeringduetoheatsourcesinthecoverage
area(seeAdjustment of Coverage AreaorTroubleshooting
section).
5. SettheamountofON-TIMEyouwantthelighttostay
onaftermotionisdetected(1,5,or10minutes).
Maximum Range Maximum
Coverage Angle*
(Top View)
FINAL ASSEMBLY
1. Pushthewiresintothejunctionbox.Makesurenone
ofthewiresgetpinched.
2.
Slidethextureassemblyontothemountingscrews.
Tightendecorativenutsremovedinstep1ofInstallation
sectionsecurelyagainstxturebase.
Junction Box
Mounting Screw
Decorative Nut
3. Installonemediumbaselightbulb(100Wattmaxi-
mum).
4. Placetopcoverontoxtureandattachusingthetwo
decorativenuts(included).Handtightenonly.
5. Caulkaroundxturebasewithsiliconeweatherseal-
ant.
Top Cover
Decorative Nut
Light Bulb (100
Watt Maximum)
Fixture Assembly
Caulk Around
Fixture Base
TEST 1 5 10
MINUTE
– +
SEN
30 ft.
(9.1 m)
6 ft.
(1.8 m)
180°