SYMPTOM
Light stays on
continuously.
Light flashes on
and off.
Light does not
stay on in Man-
ual mode.
POSSIBLE CAUSE
1. There is a heat source like an
air vent, dryer vent, or brightly-
painted, heat-reflective surface in
the coverage area. (Install shield
on sensor in the direction of heat
source.)
2. Light control is in Manual Mode.
(Switch to Auto.)
3. Light control is in DualBrite
®
mode.
4. Sensitivity is set too high. (Reduce
sensitivity.)
1. Sensor is in the Test mode. (While
in TEST mode, light only stays on
for 5 seconds.)
1. Nearby large, light-colored objects
reflecting light may trigger the
shut-off feature. Do not point other
lights at the sensor.
POSSIBLE CAUSE
1. Light switch is turned off.
2. Bulb is loose or burned out.
3. Fuse is blown or circuit breaker
is turned off.
4. Daylight turn-off is in effect (re-
check after dark).
5. Incorrect circuit wiring, if this is
a new installation.
1. Sensor may be installed in a
relatively dark location.
2. Sensor is in Test. (Set control
switch to an ON-TIME position.)
1. Sensor may be sensing small
animals or automobile traffic.
(Reduce sensitivity.)
SYMPTOM
Light will not
come on.
Light comes on
in daylight.
Light comes on
for no apparent
reason.
TROUBLESHOOTING GUIDE
TECHNICAL SERVICE
Please call 1-800-858-8501 (English speaking only) for assistance before returning
product to store.
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.hzsupport.
com. If the problem persists, call* for assistance at 1-800-858-8501 (English speaking only), 8:00 AM to
5:00 PM CST (M-F). You may also write* to:
HeathCo LLC
P.O. Box 90045
Bowling Green, KY 42102-9045
ATTN: Technical Service
* If contacting Technical Service, please have the following information available: Model Number, Date of