Instructions / Assembly

5
200067-03
FINAL ASSEMBLY
1. Attach sensor assembly to post using the three
screws supplied. Tighten screws securely.
2. Install one medium base light bulb (100 Watt
maximum).
3. Screw top cover onto top of fixture. Hand tighten
only.
SPECIFICATIONS
Range ........................... Up to 30 ft. (9.1 m)
[varies with surrounding
temperature and mount-
ing height].
Sensing Angle ..............360°
Electrical Load ..............Up to 100 Watt Maxi-
mum Tungsten Incan-
descent
Bulb Type ...................... Medium Base, Type “A”,
100 Watt Maximum
Power Requirements ....120 VAC, 60 Hz
Operating Modes .......... TEST, AUTO, Dual-
Brite
®
, and MANUAL
MODE
ON-Timer ......................1, 5, 10 minutes
DualBrite
®
Timer ..........Off, 3, 6 Hrs, Dusk-to-
Dawn
Test Timer ..................... 5 Seconds
Manual Mode Timer ......Dusk-to-Dawn
HeathCo LLC reserves the right to discontinue
products and to change specifications at any time
without incurring any obligation to incorporate new
features in products previously sold.
Glass
Fixture
Top
Cover
Light Bulb
Sensor
Assembly
Decorative
Screw (2)
Screw (3)