6
206873-02
30 ft.
(9.1 m)
6 ft.
(1.8 m)
150°
3.
Walk through the coverage area noting where
you are when the lights turn on. In TEST mode,
light will stay on for 5 seconds after sensing
motion and then turn o.
4.
Adjust the SENSITIVITY to increase or
decrease the range as needed. Too much sen-
sitivity may cause false triggering due to heat
sources in the coverage area (see
Adjustment of
Coverage Area or Troubleshooting
section).
5. Set the amount of ON-TIME you want the
light to stay on after motion is detected (1, 5,
or 10 minutes).
Maximum
Maximum Range Coverage Angle*
(Top View)
Note: When rst turned on wait about 1
1
/
2
minutes
for the circuitry to calibrate.
* resets to Auto Mode at dawn.
Least Sensitive Most Sensitive
e sensor is less sensitive to motion directly
towards it and more sensitive to motion across
coverage area.
Sensor
Motion Motion
OPERATION
Mode: On-Time Works: Day Night
Test
5 Seconds x x
Auto
1, 5, or 10
Minutes
x
Manual
To Dawn* x
... back on.
1 Second
OFF then...
Manual mode only works at
night because daylight returns
the sensor to AUTO.
Flip the light switch o for one
second then back on to toggle
between AUTO and MANUAL
MODE.
Manual mode works only with
the ON-TIME switch in the 1,
5, or 10 position.
MANUAL MODE