Instructions / Assembly

4
206873-02
OPTIONAL WIRING
is xture is provided with a sensor rated for 500 Watts. Since the xture is only rated 60 Watts, 440
Watts of additional lighting may be controlled by this sensor.
When determining what a xture is rated for, do not simply look at the rating on the lamp in the xture.
Look at the marking which species the maximum lamp wattage for which the xture is suitable.
Once you have selected the xtures to be connected and determined their maximum ratings, add these
ratings up. For instance, if you have 3 xtures rated 60 Watts, 150 Watts, and 75 Watts respectively,
you have a total load of 215 Watts.
Wiring Diagram 1 – When wiring to control a standard light xture: Strip the motion sensor’s
red wire and connect to the standard lights black wire. Connect all white wires together. Total xture
ratings must not exceed 500 Watts (4.1 A).
Wiring Diagram 2 – When wiring to control another motion sensing light xture (Master /
Slave): Strip the red wire in both light xtures. Connect the red wire of the controlling (master)
xture to the red and black wires of the controlled (slave) xture. Connect all white wires together.
Total xture ratings must not exceed 500 Watts (4.1 A).
Wiring Diagram 3 – When wiring so either motion light turns on the both motion lights
(Master / Master): Strip the red wire in both light xtures. Connect the red wire of one xture
to the red wire of the second xture. Note: In most installations, an additional wire (same gauge as
existing house wire) will have to be installed in the house to connect the two xtures as master /
master. Connect all white wires together and all black wires together. Total xture ratings must not
exceed 500 Watts (4.1 A).
Black
White
Green
or Bare
Light
Fixture
Light
Fixture
(Standard) Master Slave
Black
White
Green
or Bare
Light
Fixture
Light
Fixture
Red
Red
Wiring Diagram 1 Wiring Diagram 2
Wiring Diagram 3
Master
Black
White
Red
Green
or Bare
Master
Light
Fixture
Light
Fixture