Instruction Manual

Rizer-Line
®
Internal and External Freeze Protection System
for Automatic Waterer
No Clamp
No Tamper
Cord-Set Version
Must be protected
with GFCI
(Ground Fault
Circuit Interrupter)
General Information
Rizer-Line systems provide internal (in-pipe) and external (on-pipe) freeze
protection in one system to automatic livestock water systems and other
similar applications. These are high performance products designed to work
in extreme cold and harsh environments.
It is recommended that the Rizer-Line installation be made by a qualified
tradesperson. This will ensure that optimum performance is achieved in each
installation.
A. This heating cable set shall be installed in accordance with the National
Electrical Code (USA), and or the Canadian Electrical Code.
B. It is imperative that for all installations where the pipes are exposed to the
outside ambient temperature that weatherproof insulation be used. (Wall
thickness ½ inch minimum). Heat-Line offers closed cell foam types, foil/
air bubble type and others. Other types of weather-proof insulations may
also be used.
C. Rizer-Line can be used even when there is no water in the pipe. Rizer-Line
WILL NOT melt your water pipe. In the event of power failure your system
may freeze. The system will however re-energize immediately following
power restoration and will thaw out again. In most cases no damage to
pipes will be encountered.
Rizer-Line is a technically advanced product. Handle it with proper care and
be sure not to damage the outer sheath or jacket of the cable.
Read the Safety Instructions and Installation Instructions completely before
installing this product.
Additional Tools/Materials Required
Adjustable wrench
Cable ties and/or fiberglass tape
Teflon tape or thread sealant compound
Potable lubricant (optional)
Approvals
Dr
inking Wate
r
NSF/ANSI 61
Usage P and X
Installation Type D USA
Important Safety Instructions and Rules for safe
Installation and Operation
A. Read these rules and instructions carefully. Failure
to follow them could result in serious bodily injury
and/or property damage.
B. Before installing this product have the electrical
outlet checked by an electrician to make sure it
has been installed in accordance with the National
Electrical Code and Canadian Electrical Code. Be
certain all electrical connections are protected from
rain and other water (dry location). The heating
cable must be ground fault protected (included in
GFC models, required on site for CS models).
C. Check your local building, plumbing and electrical
codes before installing. You must comply with their
rules. Rizer-Line is cCSAus Drinking Water NSF/
ANSI 61 approved for use in Canada and the USA.
D. Before installing or servicing your Rizer-Line BE
CERTAIN that the power source is disconnected.
E. Do not use extension cords.
F. Rizer-Line is NOT approved or designed for use in
sewer or waste systems. For sewer and waste systems
use Heat-Line Paladin, EXT Series, Retro-DWS, Retro-
FM or CARAPACE systems.
G. Never tamper with or alter the electrical apparatus
associated with your Rizer-Line system.
H. Check unoccupied residences regularly to ensure
that all systems are operating properly.
WHEN PERFORMING WORK OR REPAIRS ON YOUR
WATER SYSTEM BE SURE TO UNPLUG YOUR RIZER-
LINE SYSTEM FROM THE POWER SUPPLY.
Installation Instructions
1 of 10
Kit Contents
Qty Description
1 Rizer-Line (GFC shown)
1 Optional Cord-Set (CS) power connection
Optional Accessories
HLA-120 NEMA 1 General Purpose 120V only plug-in Thermostat
MA-10 GFCI/ELCI Electrical Equipment Protection Device
INSUL-1.00 Closed cell polyethylene insulation sleeve for 1" ID pipe
(6' long, 1 5/8" ID, ¾" thick wall)
Table of Contents
Rizer-Line Typical Cross Section . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Rizer-Line Ordering Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Rizer-Line Installation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . 3
Thermostat Sensor Location and Insulation Installation . . . . . . . 5
Electrical System Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Seasonal Inspection by User . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Extended Warranty Application Form . . . . . . . . . . . . . . . . . . . . . . . 9

Summary of content (10 pages)