Quick Start Manual

10
Installation, Operation & Maintenance WDG AIR HANDLER SERIES Heat Controller, LLC
Applications
Air Handlers can be applied in up ow, down ow, horizontal
right and horizontal left applications without modi cations. For
horizontal applications, installation of an auxiliary/secondary
drain pan is required.
CAUTION!
CAUTION! For horizontal applications, the horizontal drain pan
must be located under the indoor coil. Failure to place the pan
under the coil can result in property damage.
Installation
5HWXUQ
'LVFKDUJH
TOP
DISCHARGE
5HWXUQ
'LVFKDUJH
1” to 2” Filter Rack Conversion
The unit is shipped with1” lter rack from the factory. The conversion
process is assumed that the unit is in up ow con guration.
1. Place unit on a at surface. Remove 2 knurled thumb knobs that
secure the lter rack door at the bottom of the unit.
2. Remove 3 screws that secure the lower lter tracks on each side
of the unit.
3. Lift and rotate the lter tracks upside down and reinstall lter
tracks and screws back.
4. Replace the lter rack door and the 2 knurled thumb knobs.
LEFT
DISCHARGE
5HWXUQ
'L
'LVFKDUJH
RIGHT
DISCHARGE
BOTTOM
DISCHARGE
5
'LV
5HWXUQ
'LVFKDUJH