Quick Start Manual
4
DVC/DVH Inverter Mini-Split    Heat Controller
Selecting installation place
Choose a location that places the outdoor unit as close to the indoor unit as 
possible. The maximum unit separation and vertical lift (compressor above the 
evaporator) must be taking into account. Do not exceed allowable refrigerant 
line lengths.
Indoor unit
• Unit must be installed in a location that does not obstruct the ow of air 
and ensures clearances are maintained. (Fig. 1)
• The site must support the weight of the unit.
• The site must be easily accessible for cleaning or replacement of the air 
lter, maintenance and service.
• The indoor unit should be mounted as high up on the wall toward the 
ceiling, leaving a minimum of 6” (150mm) of space between the ceiling 
and the top of the indoor unit. (Fig. 1)
• Due to the possibility of electronic interference with other devices, it is 
recommended that there should be at least to 3 ft (1 meter) between the 
unit and other devices/appliances such as televisions or radios.
• The unit should be installed away from possible exposure to re, smoke, 
of ammable gases and be protected from direct sunlight (sunlight can 
interfere with the signal between the unit and the remote controller.
Outdoor unit
• If installation location allows the unit to be exposed to strong winds (such 
as coastal applications), ensure that the unit has a wind barrier. This will 
assist with preventing strong gusts of wind from entering the unit’s cabinet 
and interfering with the fan operation. (Fig. 3 and Fig. 4)
More than
10ft.(200cm)
Fig. 1 
Fig. 2 
Fig. 3
Fig. 4
Correct
Incorrect
wind gusts
Incorrect
Strong
wind
Strong
wind
Barrier
Correct
More than
12in.(30cm)
More than 24in.(60cm)
More than 12in.(30cm)
More than 6in.(15cm)
More than 6.5ft.(2.0cm)
More than 5in.(12cm)
More than 5in.(12cm)