ASSEMBLY MANUAL 16513 04/16/2019 A Backyard Products Company VALUE SERIES GRANBURY 8' x 10' (244 x 304,8 cm) ACTUAL FLOOR SIZE: 8' x 9'- 8-1/2" (243,8 x 295,9 cm) KEEP THIS MANUAL FOR FUTURE REFERENCE IMPORTANT! READ INSTRUCTIONS THOROUGHLY PRIOR TO BEGINNING ASSEMBLY. BEFORE YOU BEGIN • BUILDING RESTRICTIONS AND APPROVALS Be sure to check with local building department and homeowners association for specific restrictions and/ or requirements before building.
TOOLS Required Phillips Screwdriver Optional Tool Belt/ Nail Pouch Utility Knife Shingle Blades Drill / Driver Tin Snips (for drip edge) Caulk Gun 5/16" Drill Bit 1/8" Drill Bit #2 Philips Drive Bit Chalk Line Paint Tools Nail Gun • gun nails Level Safety Glasses Pencil Tape Measure Square Gloves Ladder Hammer or Wood Glue Safety! Always use approved safety glasses during assembly.
CONCRETE FOUNDATION If you choose to install your kit on a concrete slab refer to the diagram below. Treated Sill Plate Caulk between sill plate and concrete. B 3-1/2" (8,9 cm) C A R DOO 4" (10,2 cm) Building Size Actual Floor Size 8'x 10' (243,8 x 304,8 cm) 8'x 9'-8-1/2" (295,9 x 235 cm) A B 96" (243,8 cm) 116-1/2" (295,9 cm) C 109-1/2" (278,1 cm) Requires: x4 2 x 4 x 8' (5,1 x 10,2 x 243,8 cm) MUST be treated lumber.
ADDITIONAL MATERIALS FOUNDATION OR FLOOR MATERIALS • This shed kit includes a complete wood floor system. • This shed kit does not include ANY leveling materials. • See the FLOOR LEVELING section on page 7 for recommended methods and suggested materials to properly level your floor, as this will vary depending on your specific site. REINFORCED WOOD FLOOR FRAME (OPTIONAL) IMPORTANT! The included floor has been designed for general use.
PARTS IDENTIFICATION AND SIZES Part identification letters are stamped on some parts. RS WOOD SIZE CONVERSION CHART Treated lumber is stamped: Nominal Board Size Actual Size 2 x 4 ..............1-1/2" x 3-1/2" (3,8 x 8,9 cm) 1 x 4 .................3/4" x 3-1/2" (1,9 x 8,9 cm) RS 2 x 3 ..............1-1/2" x 2-1/2" (3,8 x 6,3 cm) Check these locations for part stamp. 1 x 3 .................3/4" x 2-1/2" (3,8 x 6,3 cm) PARTS LIST FLOOR INVENTORY YOUR PARTS before you begin.
WALL PANELS & DOORS WALL PANELS & DOORS WALL PANEL & DOORS PARTS LIST NOTE: Panel parts are not stamped. WALL PANELS & DOORS NOTE: Panel parts are not stamped. x2 & DOORS WALL PANELS NOTE: Panel parts are not stamped. 3/8 xx2 22 x 72" (1 182,9 cm) 3/8x x55,9 22 xx72" x2 (1 182,9 cm) 3/8x x55,9 22 xx72" (1 xx2 55,9 x 182,9 cm) 3/8 x 22 x 72" (1 x 55,9 x 182,9 cm) NOTE: Panel parts are not stamped.
FLOOR LEVELING OPTIONS There are multiple ways to level your floor frame. Our recommended leveling method is shown below. Leveling materials are not included in this kit. PREFERRED METHOD - 4x4 TREATED RUNNERS • 3" Screws angled into 4x4. • (2) at each point frame • and 4x4 touch. O R 12" (30,5 cm) D O MATERIAL REQUIRED x2 4 x 4 x 10' (10 x 10 x 304,8 cm)Treated Lumber Measurements to centers of 4x4's. 12" (30,5 cm) Fasteners for Frame to 4x4. (3" Screws shown as one option.
FLOOR FRAME PARTS REQUIRED: x1 x1 x28 3" (7,6 cm) 2 x 4 x 24" (5,1 x 10,2 x 61 cm) 2 x 4 x 48" (5,1 x 10,2 x 121,9 cm) x1 2 x 4 x 68-1/2" (5,1 x 10,2 x 174 cm) x1 2 x 4 x 92-1/2" (5,1 x 10,2 x 235 cm) x6 2 x 4 x 93" (5,1 x 10,2 x 236,2 cm) BEGIN 1 Orient parts as shown on flat surface. Measure and mark. Secure using (2) 3" nails at each mark and (4) 3" nails at seams. 116 1/2" (295,9 cm) 68 1/2" (174 cm) Flush 96" (243,8 cm) 72" (182,9 cm) HINT: For easier nailing stand on frame.
LEVEL AND SQUARE FLOOR FRAME Before attaching floor decking, it is important to level and square the floor frame. A level and square floor frame is required to correctly construct your shed. BEGIN 1 See page 7 for the preferred floor leveling method. 2 Use level and check the frame is level before applying floor panels. 3 Check for frame squareness by measuring diagonally across corners. If the measurements are the same, the frame is square.
FLOOR PANELS PARTS REQUIRED: 5/8 x 48 x 96" (1,6 x 121,9 x 243,8 cm) x1 x55 GAA 2" (5,1 cm) 3/4" GAUGE BLOCK Ensure your floor frame is square by installing (1) panel and squaring frame. BEGIN 1 Install a 48" x 96" panel with the rough side up (painted-grid lines side) and with the 48" edge and corner flush to the floor frame (Fig A). Use the gauge block to mark the 3/4" measurement on joist. Secure panel using (2) 2" nails in the corners. 2 Move to the opposite side.
FLOOR PANELS PARTS REQUIRED: x152 GAA x1 5 x2 5/8 x 20-1/2 x 96" (1,6 x 52,1 x 243,8 cm) 2" (5,1 cm) 3/4" GAUGE BLOCK 5/8 x 48 x 96" (1,6 x 121,9 x 243,8 cm) Continue installing panels with rough side up (painted grid lines). Install 20-1/2" x 96" panel last. Use the gauge block to mark the 3/4" measurement on the floor joists. Secure panels using 2" nails 6" apart on edges, and 12" apart inside panels.
IMPORTANT! Check that the floor frame is level after installing floor panels. D O O R Re-level if needed. • The floor should be used as a stable work surface for wall construction. HINT: • Organize your assembly procedure during the build process to avoid over-handling of the walls.
EAVE SIDE WALLS PARTS REQUIRED: x2 NH x6 FZ x4 OZ x28 3" (7,6 cm) 2 x 3 x 46-1/4" (2,5 x 7,6 x 117,5 cm) 2 x 3 x 66-1/2" (2,5 x 7,6 x 168,9 cm) 2 x 3 x 70-1/4" (2,5 x 7,6 x 178,4 cm) YOU WILL BUILD TWO IDENTICAL EAVE SIDE WALLS BEGIN 1 Orient parts on edge on floor. Measure and mark from end of boards. Use (2) 3" nails at each mark. Use (4) nails at seams.
EAVE SIDE WALLS PARTS REQUIRED: x1 x45 3/8 x 46-1/8 x 72" (1 x 117,2 x 182,8 cm) GAA DQ 3/4" GAUGE BLOCK 2x3" GAUGE BLOCK 2" (5,1 cm) Ensure your wall frame is square by installing one panel and squaring frame. 2 Place a 46-1/8" x 72" panel onto left wall frame with primed side up as shown. Locate the panel 1-1/2" above the top plate. Use a DQ as a gauge block for the 1-1/2" top overhang measurement. Use the GAA gauge block to mark the 3/4" side measurement on the wall stud.
EAVE SIDE WALLS PARTS REQUIRED: x1 x77 3/8 x 23-7/8 x 72" (1 x 60,6 x 182,9 cm) 3/8 x 46-1/8 x 72" (1 x 117,2 x 182,8 cm) x1 GAA DQ 3/4" GAUGE BLOCK 2x3" GAUGE BLOCK 2" (5,1 cm) 4 Place 23-7/8" x 72" panel on frame as shown with primed side facing up flush with installed panel. Secure panel using 2" nails 6" apart on edges and 12" apart inside panel. 5 Place 46-1/8" x 72" panel on frame as shown with primed side facing up flush with center panel.
BACK WALL FRAME PARTS REQUIRED: x1 x1 x2 3" (7,6 cm) CI 2 x 3 x 34" (5,1 x 7,6 x 86,4 cm) PS 2 x 3 x 91 " (5,1 x 7,6 x 231,1 cm) BEGIN 1 Center PS flush on CI on edge on floor as shown (Fig. A). Nail using (2) 3" nails at connection. 91" (231,1 cm) 45-1/2" (115,6 cm) PS 45-1/2" (115,6 cm) 1-1/2" (3,8 cm) 2-1/2" (6,4 cm) Fig.
BACK WALL FRAME PARTS REQUIRED: x1 x2 CI 3" (7,6 cm) x2 2 x 3 x 34" (5,1 x 7,6 x 86,4 cm) 3" (7,6 cm) PT x1 2 x 3 x 96" (5,1 x 7,6 x 243,8 cm) 2 Center CI flush on PS on flat using a gusset as a temporary spacer. 3 Center PT on CI on edge on floor as shown. Nail PT to CI using (2) 3" Nails (Fig. A). 4 Use (2) 3" screws at middle connection (Fig. B). FINISH You have finished building your back wall frame.
BACK WALL PANELS PARTS REQUIRED: x22 2" (5,1 cm) 3/8 x 48 x 72" (1 x 121,9 x 182,9 cm) x1 BEGIN 1 Place left panel on back frame as shown with primed side facing up. Secure using 2" nails 6" apart on edges and 12" apart inside panel. Ensure 34" spacing before nailing panel. For squareness maintain flush and 3/4" measurement along panel edges.
BACK WALL PANELS PARTS REQUIRED: x11 2" (5,1 cm) x11 x1 2 1-1/2" (3,8 cm) 3/8 x 48 x 72" (1 x 121,9 x 182,9 cm) Place right panel on back frame as shown with primed side facing up and flush to panel. Ensure 34" (86,4 cm) between PT and PS. Secure using 2" nails 6" apart on edges and 12" apart inside panel. FINISH You have finished installing your back wall panels. Flush 3/4” (1,9 cm) Ensure 34" spacing before nailing panel.
FRONT WALL PARTS REQUIRED: x2 x1 x2 3/8 x 20 x 72" (1 x 50,8 x 182,9 cm x8 TEMPORARY SUPPORT BV 2" (5,1 cm) 2 x 3 x 17-1/2" (5,1 x 7,6 x 44,5 cm) PT 2 x 3 x 96" (5,1 x 7,6 x 243,8 cm) BEGIN 1 Orient PT on edge and place left panel on PT as shown with primed side facing up. Use BV as a temporary support as shown. Nail using 2" nails 4" apart. 2 Repeat step 1 for right panel.
FRONT WALL PARTS REQUIRED: x2 x6 2" (5,1 cm) BV 2 x 3 x 17-1/2" (5,1 x 7,6 x 44,5 cm) 2 Position BV on edge, 2-1/2" from outside edge and 1" from bottom edge of left wall panel (Fig A.). Nail BV to wall panel using (3) 2" Nails. 3 Repeat steps 1 - 2 for right wall panel (Fig B.).
FRONT WALL TOP PLATE PARTS REQUIRED: x5 x1 FZ 2 x 3 x 66-1/2" (5,1 x 7,6 x 168,9 cm) 3" (7,6 cm) x1 GUSSET TEMPORARY SPACER 4 Center FZ on PT on flat, flush to front wall panel (Fig. B). Secure using (5) 3" screws on angle spaced evenly. 5 Mark center of door opening for later alignment. FINISH FZ You have finished building your front wall. Fig B Flush Flush FZ 5-1/4" Front wall panel PT Use to maintain 3/8" overhang.
EAVE WALLS INSTALLATION PARTS REQUIRED (TEMPORARY): x1 x2 OO 3" (7,6 cm) x10 1-1/4 x 2-1/2 x 69" (3,2 x 7,6 x 175,3 cm) TEMPORARY SUPPORT 3" (7,6 cm) x24 2" (5,1 cm) BEGIN 1 Center right side wall assembly on the 116-1/2" floor dimension. Ensure 1-1/2" measurement is on top. 2 Use OO as a temporary brace. Secure with two 3" screws. 1-1/2" overhang OO 116-1/2 1" (2,5 cm) " (295 3" (7,6 cm) Screws D O O R .9 cm) 3 4 (Fig. A). (Nail two 3" nails between each stud through bottom plate.
BACK WALL INSTALLATION PARTS REQUIRED: x18 x14 2" (5,1 cm) x8 3" (7,6 cm) 1-1/2" (3,8 cm) x2 3" (7,6 cm) 2" (5,1 cm) It is important to secure the back wall in the following order: BEGIN 1 x1 Set back wall on side wall top plate and secure using two 3" screws on each side (Fig A). 2 (Fig. B). (Fig. C). 3 4 Nail back wall panel to eave wall stud using 1-1/2" nails 6" apart (Fig. C). 5 Secure back wall horizontal 2 x 3 using two 3" screws into back wall frame at an angle as shown (Fig. D).
FRONT WALL INSTALLATION PARTS REQUIRED: x8 x4 2" (5,1 cm) x26 3" (7,6 cm) x6 3" (7,6 cm) 1-1/2" (3,8 cm) It is important to secure the front wall in the following order: BEGIN 1 Center front wall assembly on floor, resting top plate on side walls. 2 Secure front wall top plate to side walls using (2) 3" screws (Fig. A, B). 3 4 Secure lower edge of panel to floor frame using (8) 2" nails 6" apart. Angle nail to hit floor frame (Fig. C).
RAFTERS PARTS REQUIRED: x96 6 x 24" (15,2 x 61 cm) x8 x8 x1 WI 2 x 4 x 54-1/16" (5,1 x 10,2 x 129,8 cm) 2" (5,1 cm) OO 1-1/4 x 2-1/2 x 69" (3,2 x 7,6 x 175,3 cm) TEMPORARY SUPPORT BEGIN 1 You will build FOUR assemblies; Place (2) rafter-halves WI in the corner of back and side walls. Rafters contact at peak. HINT: assemble rafters! 96” (243,8 cm) Fit base of rafters in corners of back wall.
RAFTERS x16 PARTS REQUIRED: 3" (7,6 cm) PRE-ASSEMBLED x4 BEGIN 1 Locate rafters directly over the wall studs. Ensure you have the measurements shown. 2 Screw through panel into end of rafter with 3" screw (Fig. A, Fig. B). 3 Secure with 3" screw angled from bottom of top plate into . rafter (Fig. A, Fig. B). FINISH NOTE: Measurements from outside of panels 22-3/8" (56,8 cm) 26" (66 cm) 22" (55,9 cm) 24" (61 cm) BACK OF SHED Align over studs. Maintain the measurements between rafters. Fig.
BACK WALL GABLE PANELS PARTS REQUIRED: x1 x10 LW 2 x 3 x 23-7/8" (5,1 x 7,6 x 60,6 cm) x1 x1 BEGIN 1 Place LW on flat on floor. 2 Place right gable panel primed side up, centered on LW with a 3/4" overhang on bottom. Nail using (5) 1-1/2" nails, 6" apart. 3 Place left gable panel primed side up, flush to right panel on LW with a 3/4" overhang on bottom. Nail using (5) 1-1/2" nails, 6" apart.
BACK WALL GABLE PANELS PARTS REQUIRED: x2 3" (7,6 cm) x18 2" (5,1 cm) PRE-ASSEMBLED BEGIN 1 Place gable assembly centered on back wall top plate overlapping the back wall panels 3/4" (Fig. A). 2 Nail assembly to back wall panels using 2" nails 6" apart. 3 Screw LW to top plate using (2) 3" screws (Fig. B). FINISH You have finished installing your back wall gable panels. (2) 3" (7,6 cm) Screws Fig.
FRONT WALL GABLE PANELS PARTS REQUIRED: x2 DQ x8 2 x 3 x 11-7/8" (5,1 x 7,6 x 30,2 cm) 1-1/2" (3,8 cm) x1 x1 BEGIN 1 Place DQ on flat on floor as shown. 2 Place right gable panel primed side up, centered on top DQ as shown. Secure using (2) 1-1/2" nails. 3 Orient left gable panel primed side up, flush to right panel on DQ's with a 1-1/2" overhang on bottom. Nail using (4) 1-1/2" Nails.
WINDOW INSTALL PARTS REQUIRED: x2 x1 1" (2,5 cm) 1/8" (0,3 cm)Drill Bit BEGIN 1 2 Center window in window opening as shown.Make sure frame is at an equal distance from bottom of panel (Fig. A). Secure window to DQ using (1) screw in top and bottom (Fig. B). EQUAL Fig. A (2) 1" (2,5 cm) Screws Fig.
WINDOW TRIM PARTS REQUIRED: x2 WQ x2 WO x8 1 x 2 x 11" (2,5 x 5,1 x 27,9 cm) 1-5/8" (4,1 cm) NOTE POINT 1 x 2 x 14" (2,5 x 5,1 x 35,6 cm) BEGIN 1 Center window trim on window. 2 Secure window trim using self-drilling 1-5/8" screws through window flange (Fig. A). NOTE: There will be a slight reveal inside window. FINISH You have finished installing your window trim. WO 1-5/8" (4,1 cm) Screw Fig.
FRONT WALL GABLE PANELS PARTS REQUIRED: x2 3" (7,6 cm) x18 2" (5,1 cm) PRE-ASSEMBLED BEGIN 1 Place gable assembly centered on front wall top plate overlapping front wall panels. 2 Screw DQ to top plate using (2) 3" screws (Fig. A). 3 Nail gable panels to front wall panels and LW using 2" nails 6" apart. FINISH You have finished installing your front wall gable panels. DQ (2) 3" (7,6 cm) Screws Fig.
GABLE TRIM PARTS REQUIRED: x40 1-1/4" (3,2 cm) WX x4 2 x 3 x 55-3/4" (5,1 x 7,6 x 141,6 cm) BEGIN 1 Install front gable trim WX (Fig. A) as shown. 2 Attach trim to wall using 1-1/4" screws 7-1/4" apart. Screw through panels into WX. 3 Repeat above steps 1 - 2 to secure back wall gable trim. FINISH IF YOU DO NOT HAVE THE DELUXE PACKAGE CONTINUE TO PAGE 43. Flush Fig. A Stagger Screws WX 1-1/4" (3,1 cm) Screws Flush to top of panel Flush to top of panel Center on gable panels.
ROOF PANELS PARTS REQUIRED: GAA 2" (5,1 cm) 3/4" GAUGE BLOCK 7/16 x 48 x 96" (1,1 x 121,9 x 243,8 cm) x1 x4 Roof panels may cause serious injury until securely fastened. Note: all roof panels need to be installed with the rough side up (painted grid lines). You must square the roof by attaching (1) panel first. You will use the panels’ long edge as a lever to bring your roof into square. Commonly known as “racking”. Flush at peak Fig.
ROOF PANELS PARTS REQUIRED: x1 3 4 x10 2" (5,1 cm) 7/16 x 7-7/8 x 96" (1,1 x 20 x 243,8 cm) Keep spacing between the center of the rafters at the lower edge of the panel and secure using (1) 2" nail into each rafter (Fig. E). Move to the top of the panel and keep spacing between the center of the rafters. Secure using (1) 2" nail into each rafter (Fig. E). Fig. E NOTE: Measurement from outside of trim.
ROOF PANELS PARTS REQUIRED: x1 6 x1 7/16 x 23-7/8 x 48" (1,1 x 60,6 x 121,9 cm) x12 GAA 3/4" GAUGE BLOCK 7/16 x 7-7/8 x 48" (1,1 x 20 x 121,9 cm) Install 23-7/8" x 48" and 7-7/8" x 23-7/8" roof panel flush to the installed panels and with a 1/2" measurement at the back gable trim (Fig. H). Secure panels using 2" nails 6" apart on edges and 12" apart inside panel. Gable Trim Fig.
CORNER TRIM PARTS REQUIRED: x4 x4 x56 2" (5,1 cm) 3/8 x 1-3/4 x 71-1/4" (1 x 4,4 x 181 cm) 3/8 x 1-3/4 x 71-3/4" (1 x 4,4 x 182,2 cm) BEGIN 1 Attach 71-3/4" 2 Attach 71-1/4" of 71-3/4" (Fig. A) (Fig. B) 3 4 (Fig. B) Repeat Steps 1 - 2 to attach trim to all four corners. FINISH You have attached your corner trim. Flush Gable Trim Fig. B 71-3/4" 71-1/4" 71-1/4" Flush Fig.
DOORS PARTS REQUIRED: x4 x1 3" (7,6 cm) OO x2 1-1/4 x 2-1/2 x 69" (3,2 x 7,6 x 175,3 cm) TEMPORARY SUPPORT 1-1/4" (3,2 cm) HINT: Look for 3/8" SPACER attached to doors. x1 x1 Left Door x1 GAA Right Door 1 x 3 x 5" (2,5 x 7,6 x 12,7 cm) BEGIN 1 Orient parts as shown on flat surface. (right) and green (left) on hinge board. 2 Attach temporary support OO using 3" screws in middle and at ends as shown. Tighten securely. 3 Attach temporary support GAA using (2) 1-1/4" screws as shown.
DOORS x7 PARTS REQUIRED: x1 4 3" (7,6 cm) OO 1-1/4 x 2-1/2 x 69" (3,2 x 7,6 x 175,3 cm) TEMPORARY SUPPORT Attach temporary support OO as a ledger board flush under wall panels for doors to rest on, using (3) 3" screws (Fig. A). 72" (182,9 cm) from bottom of gable panel to top of ledger board 72" from gable panels OO OO Fig. A 5 Center doors on panel seam as shown (Fig. B). Check ledger board is still flush under panels.
DOOR PARTS REQUIRED: x1 x8 WR x52 2" (5 cm) 3/4" (1,9 cm) 19/32 x 3 x 63" (1,5 x 7,6 x 160 cm) x1 x9 56" Metal Threshold 3/4" (1,9 cm) x9 Bagged separately / special coating BEGIN 1 Secure hinge boards from inside using 3/4" screws as shown (Fig. A). 2 Reinforce the door trim using 3/4" screws through door panel into trim (Fig. A). Locate screws as shown in Fig. B. Use (2) screws at seams. 3 Center trim WR over doors and secure using (8) 2" finish nails into framing as shown.
DOOR WEATHERSTRIP PARTS REQUIRED: x2 x14 2" (5 cm) OO 1-1/4 x 2-1/2 x 69" (3,2 x 7,6 x 175,3 cm) BEGIN 1 With left door closed, center a weatherstrip OO vertically on the left door in the door opening (Fig. A). OO will offset the left door 1" OUT past the door trim 1" (Fig. B). 2 Secure OO using (7) 2" screws through outside trim into OO (Fig. B) 3 On right door center OO vertically in door opening (Fig. A). OO will offset the right door 1" IN from the door trim (Fig. C).
DOOR DOOR HARDWARE PARTS REQUIRED: x4 x1 x7 x1 1" (2,5 cm) 5/16" (0,8 cm) Drill Bit 3/4" (1,9 cm) BEGIN 1 2 3 Place bolt onto OO in open position with bolt end 1/4" down from frame. Bolt is open when loop is contacting base (Fig A). Mark and pre-drill holes for screws. Install bolt with screws supplied and drill 5/16" hole for bolt to extend into door frame. Install hasp on right door and latch on left door. Bottom edge of hasp is 35-1/2" (90 cm) up from bottom edge of door trim.
PAINT & CAULK - NOT INCLUDED - • Use acrylic latex caulk that is paintable. Caulk at all horizontal and vertical seams, between the trim and walls, and all around the door trim. • Use a high quality exterior acrylic latex paint. When painting your building, there are a few key areas that can be easily overlooked that must be painted: • Bottom edge of all siding and trim • Inside of doors and all 4 edges Note: Prime all un-primed exterior wood before painting. (Follow directions provided by manufacturer.
SHINGLES - NOT INCLUDED • Follow directions provided by manufacturer and these instructions. Familiarize yourself with a 3-Tab Shingle. Notch SHINGLE NAIL PATTERN 1" (2,5 cm) 1/2" (1,3 cm) Notch Sealing Strip 1" (2,5 cm) Half A Rain Slot Full Rain Slot NAILS NEVER DRIVE FASTENERS INTO OR ABOVE SEALING STRIPS. BEGIN 1 Install first starter row upside down and color up with a 1" overhang at back and bottom of roof panel. Use (4) nails per shingle.
SHINGLES continued... 2 2 Beginning at front of shed, install first row of shingles with notch at 1" past roof edge or flush with drip edge. Roof Deck FRONT OF SHED 1" (2,5 cm) Notch - or - BACK OF SHED Flush with starter row. Drip Edge Flush with starter row. Notch 3 Install second row of shingles flush at top of first row's rain slots. Ensure 1" overhang or flush to drip edge at front, stagger each row. FRONT OF SHED BACK OF SHED 1" (2,5 cm) Notch Flush with rain slots.
SHINGLES continued... 5 Continue installing rows of shingles to the peak. At the peak make sure there is a maximum of 5" or less to the rain slot, as shown below. If shingles overlap at ridge cut to peak with a utility knife. Cut Off. 5" (12,7 cm) MAX. CUT Top of rain slot. 5" (12,7 cm) or less. • If more than 5" to rain slot you must install another row of shingles. 6 Repeat steps 1 - 5 to shingle the opposite side of your roof. Trim shingles at ridge.
SHINGLES - RIDGE CAP • You will finish off the top of the roof with a ridge cap made from shingles. BEGIN 1 Cut shingles into THREE pieces. Hint: Use cut-off pieces first. 2" (5,1 cm) 2" (5,1 cm) 2" (5,1 cm) 2" (5,1 cm) 2" (5,1 cm) 2" (5,1 cm) Score shingle, then snap-off angled cut. Weather Seal Top of slot. Note: • You will need about 20 - 22 cut pieces. 2 20 to 22 Pieces Install first ridge cap flush to shingles at front, as shown. (1) Nail per side through weather seal.
SHINGLES - RIDGE CAP continued... 4 Continue installing ridge cap to back of roof. 5 Make sure there is 4" between the shingle-color and edge of shingles. Trim cap off flush to shingles 6 When you have 4" minimum of shingle color cut one piece to cap your roof. Cut at top of rain slot. Cap 7 Install flush to shingles. Flush to shingles (2) Nails per side. FINISH 8 You have finished your ridge cap.
LIMITED CONDITIONAL WARRANTY* Backyard Storage Solutions, LLC warrants the following: 1. Every product is warranted from defects in workmanship and manufacturing for 1 year. 2. All accessories, hardware and metal components are warranted for 2 years. 3. All Oriented Strand Board (OSB) is warranted for 2 years 4. Siding and Trim is warranted for 10 years. 5. Solar Shed windows are warranted for 1 year. 6. Cedar lumber is warranted for 15 years. 7. Preserved Pine is warranted for 10 years. 8.