Installation Guide
48
7/16 x 27-1/4 x 32-5/8"
(1,1 x 69,2 x 82,9 cm)
x4
7/16 x 27-1/4 x 48"
(1,1 x 69,2 x 121,9 cm)
x4
7/16 x 32-5/8 x 48"
(1,1 x 82,9 x 121,9 cm)
x4
ROOF PANELS
2" (5,1 cm)
PARTS REQUIRED:
x230
3/4" GAUGE
BLOCK
Roof panels may cause serious injury until securely fastened.
1
BEGIN
Attach the 27-1/4" x 32-5/8" panel with a 3/4" (1,9 cm) measurement on the rafter (Fig A)
and the panel ush at the gable end overhang (Fig. B).
Secure panel with two 2" (5,1 cm) nails in the corners.
2
Attach a 48"x 96" roof panel with a 3/4" (1,9 cm) measurement on
the 5th rafter (Fig A),ush to the installed panel and ush at the
gable end overhang (Fig. B).
Secure panel with two 2" (5,1 cm) nails in the corners.
Note: all roof panels need to be installed with the rough side up (painted grid lines).
7/16 x 48 x 96"
(1,1 x 121,9 x 243,8 cm)
x2
Flush
3/4"
(1,9 cm)
Gauge
Block
Fig. A
Flush
at rafter ends.
27-1/4" x 32-5/8"
Two Nails
Fig. B
Flush at edge.
Two Nails
Flush
at rafter ends.
Fig. B
Flush
3/4"
(1,9 cm)
Gauge
Block
Fig. A
48"x 96"