Installation Guide

OPERATING INSTRUCTIONS
1. STOP! Read FOR YOUR SAFETY on page 17.
2. Unscrew ignitor cap and install a AAA type battery with the anode (+) pointing out. Replace cap.
3. Make sure manual shutoff valve is fully open.
4. Turn gas control knob clockwise to the "OFF" position, set the thermostat to lowest setting and turn
ON/OFF switch to OFF position.
5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP!
Follow "B" in the safety information label. If you don't smell gas, go to next step.
6. From "OFF" position, turn the gas control knob counterclockwise to "PILOT" position. Push in control
for 5 seconds.
7. With the control knob pushed in, push in and release the ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shutting off the
gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise to the ON position.
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON position
and adjust HI-LO knob to desired setting.
11. If the heater will not operate, follow the instructions "To Turn Off Gas To Appliance" and call your service
technician or gas supplier.
12. Wait 30 seconds before readjusting the heater when the control knob has been turned down to a lower setting.
TO TURN OFF GAS TO APPLIANCE
Push in gas Control Knob slightly and turn clockwise to the OFF position. Do not force.
MANUAL LIGHTING PROCEDURE
(match light)
1. Remove front panel .
2. Follow steps 1 through 5 under OPERATING INSTRUCTIONS.
3. With Control Knob in PILOT position, strike match, and hold near pilot. Press in Control Knob, pilot
should light.
4. Keep Control Knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release Control Knob. Follow
step 9 under OPERATING INSTRUCTIONS.
Figure 25-Pilot Figure 26-Control Plate
18