Stove User Manual

R
Page 4
November 22, 2011
Isle Royale Wood Stove
250-5763E
The Quadra-Fire Isle Royale Wood Stove meets the U.S.
Environmental Protection Agency’s 1990 particulate emis-
sion standards.
A. Appliance Certifi cation
C. Glass Specifi cations
D. BTU & Effi ciency Specifi cations
This stove is equipped with 5mm ceramic glass. Replace
glass only with 5mm ceramic glass. Please contact your
dealer for replacement glass.
EPA Certifi ed:
2.9 grams per hour
Effi ciency:
76.5%
BTU Output:
11,500 to 46,000
Heating Capacity:
2,040 to 3,500 sq ft
depending on climate zone
Vent Size:
6 inches
Firebox Size:
3.0 cubic feet
Max Wood Length:
22 inches
Fuel:
Cord Wood
Shipping Weight:
480 lbs
Model:
Isle Royale
Laboratory: OMNI Test Laboratories, Inc.
Report No & Date:
061-S-18-2
Type:
Listed Room Heater, Solid Fuel Type
Standard: UL1482, UL737, ULC S627-93
and (UM) 84-HUD, Mobile Home
Approved.
NOTE: This installation must conform with local codes. In the
absence of local codes you must comply with the UL1482, UL737,
(UM) 84-HUD and NPFA211 in the U.S.A. and the ULC S627-93
and CAN/CSA-B365 Installation Codes in Canada.
NOTE: Hearth & Home Technologies, manufacturer of
this appliance, reserves the right to alter its products,
their specifi cations and/or price without notice.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage.
For assistance or additional information, consult a qualifi ed
installer, service agency or your dealer.
Quadra-Fire is a registered trademark of Hearth & Home
Technologies.
Installation and use of any damaged appliance.
Modifi cation of the appliance.
Installation other than as instructed by Hearth & Home
Technologies.
Installation and/or use of any component part not
approved by Hearth & Home Technologies.
Operating appliance without fully assembling all
components.
Operating appliance without legs attached (if supplied
with unit).
Do NOT Overfi re - If appliance or chimney connector
glows, you are overfi ring.
Any such action that may cause a fi re hazard.
WARNING
Fire Risk.
Hearth & Home Technologies disclaims any
responsibility for, and the warranty will be
voided by, the following actions:
B. Mobile Home Approved
This appliance is approved for mobile home installa-
tions when not installed in a sleeping room and when
an outside combustion air inlet is provided.
The structural integrity of the mobile home oor, ceil-
ing, and walls must be maintained.
The appliance must be properly grounded to the frame
of the mobile home with #8 copper ground wire, and
use only listed double-wall connector pipe.
Outside Air Kit, part 831-1780 must be installed in a
mobile home installation.
1
Listing and Code Approvals