Stove User Manual

R
Page 24
November 22, 2011
Isle Royale Wood Stove
250-5763E
F. Operating The Top Loading Option
1. Using a 7/16 wrench, remove the 2 shipping bolts under-
neath the griddle before lifting the griddle off of stove.
2. Open by-pass door by moving the side handle towards
rear of stove.
3. Wait 15 seconds to allow smoke to clear out of fi rebox.
4. Slowly open top loading door and load unit with fuel.
5. Close the top door.
6. Close the by-pass door (move side handle towards front
of stove.)
NOTICE: SHIPPING BOLTS MUST BE REMOVED
PRIOR TO REMOVING GRIDDLE.
G. Heat Output Settings
For maximum operating effi ciency with the lowest
emissions, follow these operating procedures:
1. Regardless of desired heat output, when loading stove,
burn it with both air controls wide open for 5 to 15 min-
utes.
2. Regulate burn rate (heat output) by using the Primary Air
Slide Control (center under ashcatcher). The Start-Up
Air Control (on the right) is used for initial start-up and
reloading.
3. Heat output settings are listed below, following 5 to 15
minutes of burning with controls wide open (see #1
above):
4. Burn dry, well-seasoned wood.
1. High Burn Rate - Maximum Heat* - 40,000+ BTU/hr
Close Start-Up Air Control after 5 to 15 minutes, fully open
(all the way to the left) the Primary Air Slide Control.
2.
Medium-High Burn Rate* - 15,000 to 40,000 BTU/hr
Close Start-Up Air Control after 5 to 15 minutes, open the
Primary Air Slide Contro 1-1/2 inch to 1-1/8 inch.
3
.
Medium-Low Burn Rate* - 10,000 to 15,000 BTU/hr
Close Start-Up Air Control after 5 to 15 minutes, open the
Primary Air Slide Contro 1-1/8 inch to 1/2 inch.
4. Low Burn Rate* - Below 10,000 BTU/hr
Close Start-Up Air Control after 5 to 15 minutes, slide the
Primary Air Slide Control all the way to the right.
H. Burn Rates
*NOTE:
These are approximate settings, and will vary with
type of wood or chimney draft. Due to altitude and other
environmental circumstances, this operational information is
a guideline only.
Risk of extreme temperatures!
Do not operate with Start-Up Air Control in the open position
in excess of 15 minutes!
Prolonged operation with the Start-Up Air Control in the open
position may cause the combustible materials around the
stove to exceed safe temperature limits.
WARNING
NOTE: There are 3 fi ber door handles for this appliance.
They are for the door, baffl e by-pass handle and
the top-loading griddle slot.
Remove the door handle during operation to
prevent:
• Handle may overheat and may cause burns to
your hands.
Wear protective gloves when operating the draft
control knobs as they become hot during operation
WARNING
Injury Risk.
ALWAYS OPERATE THIS APPLIANCE WITH
THE DOOR CLOSED AND LATCHED EXCEPT
DURING START-UP AND RE-FUELING OR
WHEN USING THE FIRESCREEN.
OPERATING WITH THE DOOR PARTLY OPEN
CAN CAUSE:
HOT EMBERS OR SPARKS TO FALL OUT
FLAMES AND SMOKE MAY BE DRAWN OUT
FROM FIREBOX OPENING
Fire Risk.
WARNING