Page 12
November 22, 2011
Isle Royale Wood Stove
250-5763E
B. Reversible Flue Collar
The fl ue collar is reversible for either a top or rear venting
installation. The unit is shipped with the fl ue collar in the top
vent position.
Converting Collar For Rear Vent Installation
1. Remove 5 Phillips head screws from the rear shield, lift
shield up and set aside.
2. Remove bolts from each side of the fl ue transition (2
total). (Place your free hand in fl ue opening to locate
and retrieve nuts attached to bolts.)
3. Turn vent to horizontal position. Inspect sealant to ensure
a leak free application.
4. Re-assemble in reverse order.
Mounting Screws
Bend Flange Down
Please note this cover plate will not
work with the Low-Profi le Kit
Rear Flue Defl ector Cover Plate
This cover plate is used when the fl ue collar is turned for a
rear vent application.
1. After the fl ue collar has been reversed for a rear vent
installation, install the cover plate on the stove with
the two screws provided. Figure 12.2.
2. Bend the cover plate fl ange down. Figure 12.3.
3. Secure the cover plate with the remaining two screws.
Figure 12.1
Figure 12.2
Figure 12.3