user manual
19
Heat & Glo • 6000TRSI-AUC • 2078-900 Rev. G • 12/06
WARNING
FIGURE 1.29
E. IGNITION SYSTEM WIRING
• This gas fireplace is equipped with an electronic igni-
tion system which operates on a 6 volt system.
• This appliance requires 240 VAC to be wired to the
factory installed junction box. Check factory installed
power cord for damage before using.
Shock Risk
• Replace damaged wire with type
105
O
C rated wire.
• Wire must have high temperature
insulation.
CAUTION
Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation
after servicing.
IGNITION
MODULE
(6V)
ON/OFF
WALL SWITCH
VALVE
FLAME SPARKER/
SENSOR
ANT.
REMOTE
CONTROL
HOTNEUTRAL
GROUND
BATTERY PORT
VALVE
PILOT
IGNITION MODULE
6VDC
ON/OFF
SWITCH
THERMOCOUPLE
BLOCK
(CONNECTED TO
BACK OF VALVE)
GAS LINE
CONNECTED TO
BACK OF VALVE
PLUG IN