user manual
12
Heat & Glo • 6000TRSI-AUC • 2078-900 Rev. G • 12/06
FIGURE 1.13 Flueing with three 90° elbows
FLUEING WITH THREE (3) 90° ELBOWS
V H H + H
1
1´ MIN. (0.30 M) 2´ MAX. (0.61 M) 3´ MAX. (0.91 M)
2´ MIN. (0.61 M) 4´ MAX. (1.22 M) 6´ MAX. (1.83 M)
3´ MIN. (0.91 M) 6´ MAX. (1.83 M) 9´ MAX. (2.74 M)
4´ MIN. (1.22 M) 8´ MAX. (2.44 M) 12´ MAX. (3.66 M)
8´ MAX. (2.44 M) 12´ MAX. (3.66 M)
NOTE: V + V, MAX. 36´ (10.97 M)
FLUEING WITH THREE (3) 90° ELBOWS
FIGURE 1.12 Flueing with three 90° elbows
V H H + H
1
+ H
2
1´ MIN. (0.30 M) 2´ MAX. (0.61 M) 3´ MAX. (0.91 M)
2´ MIN. (0.61 M) 2´ MAX. (0.61 M) 6´ MAX. (1.83 M)
3´ MIN. (0.91 M) 4´ MAX. (1.22 M) 9´ MAX. (2.74 M)
4´ MIN. (1.22 M) 6´ MAX. (1.83 M) 12´ MAX. (3.66 M)
20´ MAX. (6.10 M) 6´ MAX. (1.83 M) 12´ MAX. (3.66 M)
H
V
H
1
V
1
H
H
1
H
2
V