User Guide

Heatilator • Caliber CNXT Series • 4047-132 Rev U • 11/0832
F. Installing Vertical Termination Baf e
Remove the glass (refer to Section 14.H.) to access
the rebox and 5 in. inner ue.
Fold the baf e (Figure 7.17) to an approximate 90°
angle (see Figure 7.18).
Note: For vertically terminated installations only.
Figure 7.17 Flat Baf e
Figure 7.18 Baf e Bent to 90° Angle
Note: If installing a vertical vent/termination run off the
top or rear of the appliance, the vertical termination baf e
supplied with the appliance may be used.
Part of the refractory must be removed before installing
the vertical baf e.
- Remove the four screws holding the refractory
retainers in place. See Figure 7.19.
Figure 7.19 Remove Refractory Retainers
- Remove the retainers.
- Remove the right or left side refractory (only one side
must be removed) by gently raising the front of the
top refractory and lifting the side piece up slightly and
pulling out. See Figure 7.20.
Push & hold the
front edge up.
Figure 7.20 Remove One Side Refractory
- Remove top by gently lowering toward side just
removed and gently twisting out. See Figure 7.21.
Figure 7.21 Remove Top Refractory