R 4100- I ACT WOOD INSERT Advanced Combustion Technology (ACT) Models: Tested and Listed by 4100I-GD-B 4100I-NL-B O-T L C US OMNI-Test Laboratories, Inc. NOTICE DO NOT DISCARD THIS MANUAL • Important operating and maintenance instructions included. • Read, understand and follow these instructions for safe installation and operation. • Leave this manual with party responsible for use and operation.
R 4100-I ACT WOOD INSERT and Welcome to the Quadra-Fire Family! Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs.
R 4100-I ACT WOOD INSERT Table of Contents SAFETY & OVERVIEW OF APPLIANCE MAINTENANCE Dimensions------------------------------------------------------ 4 Minimum Clearances to Combustibles------------------- 5 Listings----------------------------------------------------------- 6 Chimney Height & Draft and 2-10-3 Rule--------------- 6 Installation Recommendations----------------------------- 6 General Installation Procedures--------------------------- 7 Alternate Floor Protection Worksheet----------------
R 4100-I ACT WOOD INSERT DIMENSIONS 0" (762mm) 24" (610mm) CL 12-1/8" ( 08mm) 16-1/4" (41 mm) 9-5/16" (1 5mm) 7-7/8" (200mm) SIDE VIEW TOP VIEW 0 21-5/8" (549mm) o 20-7/8" (5 0mm) 10-7/8" (276mm) FRONT VIEW 45- /4" (1162mm) A Panel Size B Page A B Standard 44-3/4” (1137mm) 30-1/2” (775mm) Large 48” (1219mm) 34” (867mm) 0-7/8" (784mm) 250-7201E September 1, 2008
R 4100-I ACT WOOD INSERT CLEARANCES TO COMBUSTIBLES United States and Canada Maximum Mantel Depth - 10" (254mm) Mantel SideWall B Fascia or Trim C A D Insert E F Hearth Extension Omni Report #061-S-40-2 A B C D E F Sidewall to Stove Mantel to Stove Top Trim to Stove Side Trim to Stove Hearth Extension from Glass Hearth Extension from Side of Insert USA 15" (381mm) 26" (660mm) 20" (508mm) 6" (152mm) 16" (406mm) 8" (203mm) CANADA 15" (381mm) 23" (584mm) 20" (508mm) 6" (152mm) 18" (457mm) 8"
R 4100-I ACT WOOD INSERT LISTINGS CHIMNEY HEIGHT/DRAFT (CONT’D) These installation instructions describe the installation and operation of the Quadra-Fire 4100-I Wood Insert. This insert meets the U.S. Environmental Protection Agency’s 1990 particulate emission standards. This product is listed by OMNI-Test Laboratories, Inc. to UL Safety Standard 1482, and ULC S628, and (UM) 84-HUD.
R 4100-I ACT WOOD INSERT GENERAL INSTALLATION PROCEDURE • • • • • • • • • • • DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. Install liner, if required, for your chosen installation. Attach metal warning plate to the back of the fireplace with screws or nails. Set appliance on the hearth (See Hearth Requirements page 5 and Support Kit information on page 16.) Complete the vent connection required for your installation type. Relocate plate for Outside Air.
R 4100-I ACT WOOD INSERT CHIMNEY REQUIREMENTS A chimney must be the required height above the roof or other obstruction for safety and for proper draft operation. The requirement is that the chimney must be at least 3 feet (91cm) higher than the highest point where it passes through the roof, and at least 2 feet (61cm) higher than the highest part of the roof or structure that is within10 feet (305cm) of the chimney, measured horizontally. Refer to Figure 8C.
R 4100-I ACT WOOD INSERT INSTALLATIONS INTO ZERO CLEARANCE FIREPLACES IN MOBILE HOMES Spark Arestor Cap (IN USA ONLY) 1. An outside air inlet must be provided for combustion and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted while unit is in use to prevent room air starvation which can cause smoke spillage and an inability to maintain a fire. Smoke spillage can also set off smoke alarms. 2. Unit must be secured to the mobile home structure.
R 4100-I ACT WOOD INSERT INSTALLATION OPTIONS Refer to: Clearances to Combustibles on page 5, Canadian Installation requirements on page 12, Hearth Requirements on page 5 and Zero Clearance Adjustable Support Kit on page 16.
R 4100-I ACT WOOD INSERT Factory-built zero clearance fireplace (usa installations only) The Quadra-Fire 4100-I ACT Wood Stove Insert is listed to UL 1482 Standard and approved for installation into listed factory built zero clearance fireplaces listed to UL 127 conforming to the following specifications and instructions: The original factory-built clearance fireplace chimney cap must be re-installed after installing the approved chimney liner meeting type H.T. requirements (2100°F) per UL 1777.
R 4100-I ACT WOOD INSERT INSTALLATION IN CANADA MASONRY and HEAT-CIRCULATING (INSTALLATIONS INTO FACTORY-BUILT FIREPLACES ARE PROHIBITED IN CANADA) Whether installed in a masonry or heat-circulating fireplace, this fireplace insert must be installed with a continuous chimney liner of six inch (152mm) diameter extending from the fireplace insert to the top of the chimney.
R 4100-I ACT WOOD INSERT SECURING LINER TO CHIMNEY RING There are two options to secure the liner to the chimney ring: See Figure 13A. Option One: If there is enough room on the top of the insert to work, hand bend the two tabs upward 90°. Secure the liner with the supplied hex head bolts 1/420-3/4. 2 pre-drilled holes on chimney ring under outer skin (access through firebox) Option Two: Remove the manifold tubes, fiberboard baffle and ceramic blanket.
R 4100-I ACT WOOD INSERT PANEL SET and CAST TRIM SET STANDARD SIZE: 30-1/2” h x 44-3/4”w LARGE SIZE: 34”h x 48”w Panel and Cast Trim must be ordered separately. Included in Panel Kit: (2) side panels, left and right; (1) panel top; (2) trim pieces; (1) trim top; (1) fastener package. Included in Cast Trim Kit: (2) cast trim legs, left and right; (1) cast trim header; (2) cast trim footers, left and right. Tools Needed: Powered Phillips Head Screw Driver 1. 2. 3. 4. 5. 6. 7.
R 4100-I ACT WOOD INSERT BLOWER CORD LOCATION & BLOWER CONTROL BOX WITH SWITCH FAN (BLOWER) REPLACEMENT This insert comes standard with a blower, installed at the factory with blower cord on right side of insert (as you face the unit). The blower cord can also be installed on the left side. Disconnect the cord from right side. ROUTE WIRES IN FRONT OF FAN. Re-install on the left side. Do not route cord behind the cooling fan.
R 4100-I ACT WOOD INSERT ZERO CLEARANCE ADJUSTABLE TRIM SUPPORT Two sizes: 9”d x 45”w and 12”d x 50”w, both 2” to10” Height Adjustment Included in Kit: (1) Trim Top, (1) Trim Front, (2) Trim Sides, Double-Sided Tape (already installed) Tools Needed: Phillips Head Screwdriver, Sheet Metal Shears, Measuring Tape, Gloves 1. The 10 screws on each set of scissors will already be loose when shipped. Figure 16A. 2. Expand scissors to desired height.
R 4100-I ACT WOOD INSERT OPERATION WOOD SELECTION AND STORAGE Burn only dry seasoned wood. Dry, well-seasoned wood will not only minimize the chance of creosote formation but will give you the most efficient heat output. Even dry wood contains at least 15% moisture by weight and should be burned hot enough to keep the chimney hot enough to maintain particulate (smoke) burning. Burning unseasoned wood of any variety defeats the inserts’ efficiency.
R 4100-I ACT WOOD INSERT OPERATING TIPS HEAT OUTPUT RATES For maximum operating efficiency with the lowest emissions, follow these operating procedures: 1. Regardless of desired heat output, when loading insert, burn your Quadra-Fire with both air controls wide open for a minimum of 5 to 15 minutes. 2. Regulate burn rate (heat output) by using the Primary Control (top rod). The Start-Up Air Control (bottom rod) is used for initial start-up and reloading. 3.
R 4100-I ACT WOOD INSERT BURNING PROCESS Final Stage In recent years there has been an increasing concern about air quality. Much of the blame for poor air quality has been placed on the burning of wood for home heating. In order to improve the situation, we at Quadra-Fire have developed cleaner-burning wood stoves and inserts that surpass the requirements for emissions established by our governing agencies.
R 4100-I ACT WOOD INSERT MAINTENANCE CARE AND CLEANING OF PLATED SURFACES IMPORTANT: You must clean all the fingerprints and oils from the plated surfaces before firing the insert for the first time. Use warm soapy water and a soft rag, glass cleaner and a paper towel, or vinegar and a paper towel to remove the oils. DO NOT use abrasive cleaners! If not cleaned properly prior to lighting the first fire, the oils can cause permanent stains.
R 4100-I ACT WOOD INSERT brick replacement instructions The firebox is lined with high quality firebrick which has exceptional insulating properties. There is no need for a grate, simply build a fire on the firebox of your insert. 1. 6 1 1 4 4 6 Be certain coals are completely cold. Remove all old brick and ash from unit and vacuum out firebox. 2. Remove new brick set from box and lay out to THE diagram as shown. 5 5 4 3. Lay bottom bricks in unit. 4 4 4.
R 4100-I ACT WOOD INSERT EXPLODED VIEWS 15 18 17 14 16 13 9 19 12 8 11 10 20 5 1 7 6 2 21-1/2" 3 10.0" 4 5.0" R5" Ceramic Blanket 14.
R 4100-I ACT WOOD INSERT Service Parts and Accessories IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on the Quadra-Fire web site at www. quadrafire.com. When ordering, supply serial and model numbers to ensure correct part.
R 4100-I ACT WOOD INSERT Item # 16 Part Description Alphabetical Order SKU Top, Cast 435-0300 Trim, Cast, Footer, Left 414-7090MBK Trim, Cast, Footer, Right 414-7100MBK Trim, Cast, Header 414-7110MBK Trim, Cast, Leg, Left 414-7120MBK Trim, Cast, Leg, Right 414-7130MBK Trim, Cast, Set, Matte Black (5 piece) 811-0930 20 Trim, Ring, Front, Gold 435-0570 20 Trim, Ring, Front, Nickel 435-0990 31 Trim, Ring, Side, Gold 435-0580 31 Trim, Ring, Side, Nickel 435-1000 6 Wire Harness On
R 4100-I ACT WOOD INSERT Service and Maintenance Log Date of Service September 1, 2008 Performed By Description of Service 250-7201E Page 25
R 4100-I ACT WOOD INSERT Warranty Policy Hearth & Home Technologies LIMITED WARRANTY Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or Canada. Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.
R 4100-I ACT WOOD INSERT Hearth & Home Technologies LIMITED WARRANTY (Cont’d) HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or maintenance of the appliance not in accordance with the installation instructions; operating instructions and the listing agent identification label furnished with the appliance; (2) installation which does not comply with local building codes; (3) shipping, improper handling, improper operation, abuse, misuse, accid
R CONTACT INFORMATION: Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer, log onto www.quadrafire.com CAUTION • Do NOT discard this manual. • Important operating and maintenance instructions included. • Read, understand and follow these instrucitons for safe installation and operation.