Reference Manual

HEARTTECHENTERPRISECO .,LTD. BESTSERVICEFROMHEART
9of10
RemoteI/Oportpinarrangement:
TheRemoteI/OTargettype:HandReaderandControllerI/OPanel
PinNo. Signalname
Symbol
Direction Comment
HandReader
Controller
I/OPanel
1
PowerSupplytoRemoteI/O
Target
VCC(DC5V)‐
2 RedorRightStatusLED RedLED RightLED Output
3 GreenorLeftStatusLED GreenLED LeftLED Output
4 BuzzerorRightButton Buzzer RightButton Output Input
5 PushButtonorLeftButton PushButton LeftButton Input
6 CommonGround GND‐
7
AntennaCoil
Antcoil1 ‐‐‐‐ ‐‐‐‐
8 Antcoil2 ‐‐‐‐ ‐‐‐‐
HandReaderOperationBriefDescription:
(1) Whenthe PushButtonoftheHandReaderwaspress by op erator,the RedLED of theHandReaderis
turnedonandtheHandReaderbeginstoaccesstheTIRISTag.
(2) WhileHand Reader is accessing theTIRIS Tag, the RedLED is turned on until theCID/data is accessed
successfullyorfailureandtheCID/dataormessageistransmittedtothehostsystemcompletedorthe
accesstimeover1secondortheCIDRead/WritecontrollerreceivesanewcommandfromHostsystem,
theRedLEDwillbeturnedoff.
(3) When the CID/data is accessed
successfully, the GreenLED is turned on. If the CID/data is accessed
failureortheCIDRead/Writecontroller requestreadyto sendbuttheHosthasnoresponse over500
ms,theRedLEDandBuzzeristurnedonandoffshortbeepfor3times.
ControllerI/OPanelOperationBriefDescription:
(1) When the LeftButton or RightButton of the Controller I/O panel was press by operator, the LeftLED
andRightLEDof Controller I/Opanel is turnedonand the CID Read/Writecontroller beginstoaccess
theTIRISTag.
(2) Whenthe CID Read/Write controllerreceives accessing RFIDTagcommandfromtheHostsystem,the
LeftLEDandRightLEDofController I/OpanelisturnedontogetherandtheCIDRead/Writecontroller
beginstoaccesstheTIRISTag.
(3) TheLeftLEDandRightLEDstatuswillnotchange duringtheCIDRead/Write controllerisaccessingthe
TIRIS Tag. When the CID/data is accessed successfully and the CID/data is transmitted to the host