Reference Manual
HEARTTECHENTERPRISECO .,LTD. BESTSERVICEFROMHEART
9of10
RemoteI/Oportpinarrangement:
TheRemoteI/OTargettype:HandReaderandControllerI/OPanel
PinNo. Signalname
Symbol
Direction Comment
HandReader
Controller
I/OPanel
1
PowerSupplytoRemoteI/O
Target
VCC(DC5V)‐‐‐‐
2 RedorRightStatusLED Red‐LED Right‐LED Output
3 GreenorLeftStatusLED Green‐LED Left‐LED Output
4 BuzzerorRight‐Button Buzzer Right‐Button Output Input
5 Push‐ButtonorLeft‐Button Push‐Button Left‐Button Input
6 CommonGround GND‐‐‐‐
7
AntennaCoil
Antcoil1 ‐‐‐‐ ‐‐‐‐
8 Antcoil2 ‐‐‐‐ ‐‐‐‐
■HandReaderOperationBriefDescription:
(1) Whenthe Push‐ButtonoftheHandReaderwaspress by op erator,the Red‐LED of theHandReaderis
turnedonandtheHandReaderbeginstoaccesstheTIRISTag.
(2) WhileHand Reader is accessing theTIRIS Tag, the Red‐LED is turned on until theCID/data is accessed
successfullyorfailureandtheCID/dataormessageistransmittedtothehostsystemcompletedorthe
accesstimeover1secondortheCIDRead/WritecontrollerreceivesanewcommandfromHostsystem,
theRed‐LEDwillbeturnedoff.
(3) When the CID/data is accessed
successfully, the Green‐LED is turned on. If the CID/data is accessed
failureortheCIDRead/Writecontroller requestreadyto sendbuttheHosthasnoresponse over500
ms,theRed‐LEDandBuzzeristurnedonandoffshortbeepfor3times.
■ControllerI/OPanelOperationBriefDescription:
(1) When the Left‐Button or Right‐Button of the Controller I/O panel was press by operator, the Left‐LED
andRight‐LEDof Controller I/Opanel is turnedonand the CID Read/Writecontroller beginstoaccess
theTIRISTag.
(2) Whenthe CID Read/Write controllerreceives accessing RFIDTagcommandfromtheHostsystem,the
Left‐LEDandRight‐LEDofController I/OpanelisturnedontogetherandtheCIDRead/Writecontroller
beginstoaccesstheTIRISTag.
(3) TheLeft‐LEDandRight‐LEDstatuswillnotchange duringtheCIDRead/Write controllerisaccessingthe
TIRIS Tag. When the CID/data is accessed successfully and the CID/data is transmitted to the host