Page 58 of 63 Report No.: CQASZ20210400194S
IEC 62368-1 with U.S.A. National differences
Clause Requirement + Test Result - Remark Verdict
Annex
DVA
(G.4.2)
Equipment with isolated ground (earthing)
receptacles complies with NEC 250.146(D) and
CEC 10-112 and 10-906(8).
N/A
Annex
DVA
(G.4.3)
Where a fuse is used to provide Class 2 or Class 3
current limiting, it is not operator-accessible unless
it is non- interchangeable.
P
Annex
DVA
(G.5.3)
Power distribution transformers distributing power
at 100 volts or more, and rated 10 kVA or more,
require special transformer overcurrent protection.
N/A
Annex
DVA
(G.5.4)
Motor control devices are required for cord-
connected equipment with a mains-connected
motor if the equipment is rated more than 12 A, or if
the equipment has a nominal voltage rating greater
than 120 V, or if the motor is rated more than 1/3
hp (locked rotor current over 43 A).
N/A
Annex
DVA
(Annex M)
For ITE room applications, equipment with battery
systems capable of supplying 750 VA for five
minutes have a battery disconnect means that may
be connected to the ITE room remote power-off
circuit.
N/A
Annex
DVA (Q)
Wiring terminals intended to supply Class 2 outputs
according to the NEC or CEC Part 1are marked
with the voltage rating and “Class 2” or equivalent;
marking is located adjacent to the terminals and
visible during wiring.
N/A
Annex
DVB (1)
Additional requirements apply for equipment used
for entertainment purposes intended for installation
in general patient care areas of health care
facilities.
N/A
Annex
DVC (1)
Additional requirements apply for equipment
intended for mounting under kitchen cabinets.
N/A