Page 57 of 63 Report No.: CQASZ20210400194S
IEC 62368-1 with U.S.A. National differences
Clause Requirement + Test Result - Remark Verdict
Consumer products designed or intended primarily
for children 12 years of age or younger are subject
to additional requirements in accordance with U.S.
& Canadian Regulations.
N/A
Baby monitors additionally comply with ASTM
F2951, Consumer Safety Specification for Baby
Monitors.
N/A
Annex
DVA
(5.6.3)
For Pluggable Equipment Type A, the protection in
the installation is assumed to be 20A.
P
Annex
DVA (6.3)
The maximum quantity of flammable liquid stored
in equipment complies with NFPA 30.
N/A
Annex
DVA
(6.4.8)
For ITE room applications, enclosures with
combustible material measuring greater than 0.9
m
2
(10 sq ft) or a single dimension greater than 1.8
m (6 ft) have a flame spread rating of 50 or less.
For equipment with the same dimensions for other
applications, an external surface that is not a fire
enclosure requires a min. flammability classification
of V-1.
N/A
Annex
DVA
(10.3.1)
Equipment with lasers meets the U.S. Code of
Federal Regulations 21 CFR 1040 (and the
Canadian Radiation Emitting Devices Act, REDR
C1370).
N/A
Annex
DVA
(10.5.1)
Equipment that produces ionizing radiation
complies with the U.S. Code of Federal
Regulations, 21 CFR 1020 (and the Canadian
Radiation Emitting Devices Act, REDR C1370).
N/A
Annex
DVA
(F.3.3.3)
Equipment for use on a.c. mains supply systems
with a neutral and more than one phase conductor
(e.g. 120/240 V, 3-wire) require a special marking
format for electrical ratings. Additional
considerations apply for voltage ratings that exceed
the attachment cap rating or are lower than the
“Normal Operating Condition” in Table 2 of
CAN/CSA C22.2 No. 235.”
N/A
Annex
DVA
(F.3.3.5)
Equipment identified for ITE (computer) room
installation is marked with the rated current
N/A
Annex
DVA (G.1)
Vertically-mounted disconnect switches and circuit
breakers have the "on" position indicated by the
handle in the up position
N/A
Annex
DVA
(G.3.4)
Suitable NEC/CEC branch circuit protection rated
at the maximum circuit rating is required for all
standard supply outlets and receptacles (such as
supplied in power distribution units) if the supply
branch circuit protection is not suitable.
N/A