Safety Information
Page 55 of 63 Report No.: CQASZ20210400194S
IEC 62368-1 with U.S.A. National differences
Clause Requirement + Test Result - Remark Verdict
ATTACHMENT TO TEST REPORT IEC 62368-1 2
th
Ed.
U.S.A. NATIONAL DIFFERENCES
Audio/video, information and communication technology equipment – Part 1: Safety requirements
Differences according to ................: CSA/UL 62368-1:2014
Attachment Form No. .....................: US&CA_ND_IEC623681B
Attachment Originator ....................: UL(US)
Master Attachment ..........................: Date 2015-06
Copyright © 2015 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE),
Geneva, Switzerland. All rights reserved.
IEC 62368-1 - US and Canadian National Differences
Special National Conditions based on Regulations and Other National Differences
1.1 All equipment is to be designed to allow installation
according to the National Electrical Code (NEC),
ANSI/NFPA 70, the Canadian Electrical Code
(CEC), Part I, CAN/CSA C22.1, and when
applicable, the National Electrical Safety Code,
IEEE C2.
Also, for such equipment marked or otherwise
identified, installation is allowed per the Standard
for the Protection of Information Technology
Equipment, ANSI/NFPA 75.
P
1.4 Additional requirements apply to some forms of
power distribution equipment, including sub-
assemblies.
N/A
4.1.17 For lengths exceeding 3.05 m, external
interconnecting flexible cord and cable assemblies
are required to be a suitable cable type (e.g., DP,
CL2) specified in the NEC.
N/A
For lengths 3.05 m or less, external interconnecting
flexible cord and cable assemblies that are not
types specified in the NEC generally are required
to have special construction features and
identification markings.
N/A
4.8 Lithium coin / button cell batteries have modified
special construction and performance
requirements.
N/A
5.6.3 Protective earthing conductors comply with the
minimum conductor sizes in Table G.5, except as
required by Table G.7ADV.1 for cord connected
equipment, or Annex DVH for permanently
connected equipment
P
5.7.7 Equipment intended to receive telecommunication
ringing signals complies with a special touch
current measurement tests.
N/A