Safety Information
Page 50 of 63 Report No.: CQASZ20210400194S
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
B.4 TABLE: Fault condition tests
P
Ambient temperature (C) ............................................................. :
See below
Power source for EUT: Manufacturer, model/type, output rating . : See below
Component
No.
Fault
Condition
Supply
voltage,
(V)
Test time
(ms)
Fuse
no.
Fuse
current,
(A)
T-couple Temp.
(C)
Observation
T1 Pin 1-2 SC 264V 10mins F1 0.020 -- -- EUT shutdown
immediately
after shorted.
Duration the
test, no fire,
no hazards
occur.
T1 Pin 3-5 SC 264V 10mins F1 0.021 -- -- EUT shutdown
immediately
after shorted.
Duration the
test, no fire,
no hazards
occur.
T1 Pin 6-7 SC 264V 10mins F1 0.020 -- -- EUT shutdown
immediately
after shorted.
Duration the
test, no fire,
no hazards
occur.
U2 SC 264V 10mins F1 0.021 -- -- EUT shutdown
immediately
after shorted.
Duration the
test, no fire,
no hazards
occur.
C6 SC 264V 10mins F1 0.020 -- -- EUT shutdown
immediately
after shorted.
Duration the
test, no fire,
no hazards
occur.
Supplementary information:
1) OL: overload. SC: short circuit. OC: open circuit
2) The Hi-pot test conducted successfully after the completion of fault condition test.
3) Output terminal does not exceed ES1 limits.