Safety Information
Page 49 of 63 Report No.: CQASZ20210400194S
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
Ambient temperature (C) ............................................................. :
See below
Power source for EUT: Manufacturer, model/type, output rating . : See below
Component
No.
Fault
Condition
Supply
voltage,
(V)
Test time
(ms)
Fuse
no.
Fuse
current,
(A)
T-couple Temp.
(C)
Observation
USB output SC 264V 10min F1 0.021 -- -- EUT shutdown
immediately
after shorted.
Duration the
test, no fire,
no hazards
occur.
USB output
(Type C)
SC 264V 10min F1 0.021 -- -- EUT shutdown
immediately
after shorted.
Duration the
test, no fire,
no hazards
occur.
DB1 SC 264V 10s F1 0 -- --
F1 opened
immediately
after shorted.
Duration the
test, no fire,
no hazards
occur.
C2 SC 264V 10s F1 0 -- --
F1 opened
immediately
after shorted.
Duration the
test, no fire,
no hazards
occur.
Q1 Pin S-D SC 264V 10s F1 0 -- --
F1 opened
immediately
after shorted.
Duration the
test, no fire,
no hazards
occur.