Safety Information

Page 48 of 63 Report No.: CQASZ20210400194S
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
B.2.5 TABLE: Input test
P
U (V) I (A) I rated (A) P (W) P rated (W) Fuse No I fuse (A) Condition/status
90V/60Hz
0.370 -- 19.25
-- F1
0.370
Normal operation
100V/60Hz
0.336 -- 19.06
-- F1
0.336
Normal operation
240V/60Hz
0.177 -- 18.99
-- F1
0.177
Normal operation
264V/60Hz
0.165 -- 19.12
-- F1
0.165
Normal operation
90V/50Hz
0.363 -- 19.29
-- F1
0.363
Normal operation
100V/50Hz
0.331 -- 19.02
-- F1
0.331
Normal operation
240V/50Hz
0.179 -- 18.99
-- F1
0.179
Normal operation
264V/50Hz
0.166 -- 19.13
-- F1
0.166
Normal operation
Supplementary information:
Max. normal load:Type C output: 5Vdc. 3.1A
B.3 TABLE: Abnormal operating condition tests
P
Ambient temperature (C) ............................................................. :
See below
Power source for EUT: Manufacturer, model/type, output rating . : See below
Component
No.
Abnormal
Condition
Supply
voltage,
(V)
Test time
(ms)
Fuse
no.
Fuse
current,
(A)
T-
couple
Temp.
(C)
Observation
USB output
(Type C)
OL 264V 4h02mins F1 Max.
0.223
K
T1 winding:
116.6°C
T1 core:
109.2°C
Enclosure:
58.3°C
Ambient:
25.0°C
Unit shutdown
output
overloaded to
3.45A.
Recoverable.
No hazard.
Supplementary information:
1) OL: overload.
2) The Hi-pot test conducted successfully after the completion of fault condition test.
3) Output terminal does not exceed ES1 limits.
4) Temperature limits under the fault condition:
Power Transformer: 165°C
Enclosure outside: 87°C
B.4 TABLE: Fault condition tests
P