Safety Information
Page 45 of 63 Report No.: CQASZ20210400194S
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
5.5.2.2 TABLE: Stored discharge on capacitors
N/A
Supply Voltage (V), Hz Te s t
Location
Operating
Condition
(N, S)
Switch
position
On or off
Measured Voltage
(after 2 seconds)
ES Classification
-- -- -- -- -- --
Supplementary information:
X-capacitors installed for testing are:
bleeding resistor rating:
ICX:
Notes:
A. Test Location: Phase to Neutral; Phase to Phase; Phase to Earth; and/or Neutral to Earth
B. Operating condition abbreviations:
N – Normal operating condition (e.g., normal operation, or open fuse); S –Single fault condition
C. The resistor passed G.10.1 and G.10.2 of IEC62368-1 test, so no need to perform discharge test under
single fault condition
5.6.6.2 TABLE: Resistance of protective conductors and terminations
P
Accessible part Test current
(A)
Duration
(min)
Voltage drop
(V)
Resistance
(Ω)
Plug G pin to socket G pin 20 2 -- 0.012
Supplementary information:
5.7.2.2,
5.7.4
TABLE: Earthed accessible conductive part
N/A
Supply voltage ............................................................. : —
Location Test conditions specified in 6.1 of
IEC 60990 or Fault Condition No
in IEC 60990 clause 6.2.2.1
through 6.2.2.8, except for 6.2.2.7
Touch current
(mA)
1
2*
3
4
5
6
8
Supplementary Information:
Notes:
[1] Supply voltage is the anticipated maximum Touch Voltage
[2] Earthed neutral conductor [Voltage differences less than 1% or more]