Safety Information

Page 35 of 63 Report No.: CQASZ20210400194S
IEC 62368-1
Clause Requirement + Test Result - Remark Verdict
S.3 Flammability test for the bottom of a fire
enclosure
N/A
Samples, material ............................................... :
Wall thickness (mm) ............................................ :
Cheesecloth did not ignite N/A
S.4 Flammability classification of materials N/A
S.5 Flammability test for fire enclosures and fire
barrier materials of equipment where the steady
state power does not exceed 4 000 W
N/A
Samples, material ............................................... :
Wall thickness (mm) ............................................ :
Conditioning (test condition), (C) ....................... :
Test flame according to IEC 60695-11-20 with
conditions as set out
N/A
After every test specimen was not consumed
completely
N/A
After fifth flame application, flame extinguished
within 1 min
N/A
T MECHANICAL STRENGTH TESTS P
T.1 General requirements P
T.2 Steady force test, 10 N ...................................... : (See appended table T.2) P
T.3 Steady force test, 30 N ...................................... : (See appended table T3) N/A
T.4 Steady force test, 100 N .................................... : (See appended table T4) N/A
T.5 Steady force test, 250 N .................................... : (See appended table T5) P
T.6 Enclosure impact test (See appended table T6) P
Fall test P
Swing test P
T.7 Drop test ............................................................ : (See appended table T7) N/A
T.8 Stress relief test ................................................... : (See appended table T8) P
T.9 Impact Test (glass) N/A
T.9.1 General requirements N/A
T.9.2 Impact test and compliance N/A
Impact energy (J) ................................................... :
Height (m) .............................................................. :
T.10 Glass fragmentation test ....................................... : (See sub-clause 4.4.4.9) N/A
T.11 Test for telescoping or rod antennas N/A