Performance Data Sheet
9-6000302 Rev. 1
3
VOC Claims included by surrogate testing of Chloroform*
It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as
advertised. See Installation Manual for Warranty information.
Application Guidelines/Water Supply Parameters
Service Flow 0.5 gpm (21.9 lpm)
Water Supply Potable Water
Water Pressure 40-120 psi (2.8-8.2 bar)
Water Temperature 33°F-100°F (0.6°C-38°C)
NOTE: While the testing was performed under standard laboratory
conditions, actual performance may vary.
WARNING
To reduce the risk associated with ingestion of contaminants:
• Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before and after the
system. Systems certified for cyst reduction may be used on disinfected
water that may contain filterable cysts.
NOTICE
To reduce the risk associated with property damage due to water
leakage:
• Read and follow use instructions before installation and use of this
system.
• Installation and use must comply with all state and local plumbing codes.
• Do not install if water pressure exceeds 120 psi (8.2 bar). If your water
pressure exceeds 80 psi, you must install a pressure-limiting valve.
Contact a plumbing professional if you are uncertain how to check your
water pressure.
• Do not install where water hammer conditions may occur. If water
hammer conditions exist you must install a water hammer arrester.
Contact a plumbing professional if you are uncertain how to check for
this condition.
• Do not install on hot water supply lines. The maximum operating water
temperature of this filter system is 100º F (38º C).
• Protect filter from freezing. Drain filter when temperatures drop below
33ºF (0.6ºC).
• The disposable filter cartridge should be replaced every 6 months at the
rated capacity, or sooner if a noticeable reduction in flow rate occurs.
The contaminants or other substances removed or reduced by this water filter
are not necessarily in all users’ water.
C
Certified by IAPMO R&T to NSF/ANSI 42, 53, 401, NSF
P473 and CSA B483.1 for the reduction claims specified on
the Performance Data Sheet and at www.Iapmo.org, and
to NSF/ANSI 372 for Low Lead content.
* VOC claim only valid on filters made in Taiwan (see package or product label)
Substance Tested for Reduction NSF/ANSI 53 specified challenge
concentration (mg/L)
Max Permissible product water concentration /
NSF reduction requirements (mg/L)
Average %
Reduction
dinoseb 0.170 0.0002 99
endrin 0.053 0.00059 99
ethylbenzene 0.088 0.001 >99
ethylene dibromide (EDB) 0.044 0.0002 >99
haloacetonitriles (HAN)
bromochloroacetonitrile
dibromoacetonitrile
dichloroacetonitrile
trichloroacetonitrile
0.022
0.024
0.0096
0.015
0.0005
0.0006
0.0002
0.0003
98
98
98
98
haloketones (HK)
1,1-dichloro-2 propanone
1,1,1-trichloro-2-propanone
0.0072
0.0082
0.0001
0.0003
99
96
heptachlor {H-34, heptox) 0.025 0.00001 >99
heptachlor epoxide 0.0107
f
0.0002 98
hexachlorobutadiene 0.044 0.001 >98
hexachlorocyclopentadiene 0.060 0.000002 >99
lindane 0.055 0.00001 >99
methoxychlor 0.050 0.0001 >99
pentachlorophenol 0.096 0.001 >99
simazine 0.120 0.004 >97
styrene 0.150 0.0005 >99
1,1,2,2-tetrachloroethane 0.081 0.001 >99
tetrachloroethylene 0.081 0.001 >99
toluene 0.078 0.001 >99
2,4,5-TP (silvex) 0.270 0.0016 99
tribromoacetic acid 0.042 0.001 >98
1,2,4-trichlorobenzene 0.160 0.0005 >99
1,1,1-trichloroethane 0.084 0.0046 95
1,1,2-trichloroethane 0.150 0.0005 >99
trichloroethylene 0.180 0.0010 >99
trihalomethanes (includes)
chloroform (surrogate chemical)
bromoform
bromodichloromethane
chlorodibromomethane
0.300 0.015 95
xylenes (total) 0.070 0.001 >99