Refrigerator Water Filter Models:
FMF-2
HDX • 2455 Paces Ferry Rd. N.W. • Atlanta, GA 30339 • 1-855-849-3589
Flow Rate: 0.5 gpm / 1.89 lpm
Operating Temperature: 33 - 100°F (0.6°C - 38°C)
Operating Pressure: 30 psi (207 kPa) - 100 psi (689 kPa)
Capacity: 200 gallons (757 L) or six months
FILTER SPECIFICATIONS
Performance Data Sheet
This system has been tested according to NSF/ANSI Standard 42, 53, 372, 401, P473 and CSA B483.1 for reduction of the substances
listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or
equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42, 53, 372, 401, P473 and CSA B483.1.
Systems certified for cyst reduction may be used on disinfected waters that may contain filterable
cysts. The system conforms to NSF/ANSI 42, 53, 372, 401, P473 and CSA B483.1 for the specific
performance claims as verified and substantiated by test data. Conforms to NSF/ANSI 53 for VOC
reduction. See above for individual contaminants and reduction performance. Note: Testing was
performed under standard laboratory conditions, actual performance may vary.
System to be used with municipal or well water sources treated and tested on regular basis to ensure
bacteriological safe quality. Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.
It is essential that the manufacturer’s recommended installation, maintenance and filter replacement
requirements be carried out for the product to perform as advertised. Manufactured by Aquamor, LLC,
Temecula, CA.
Limited Warranty: This filter hereunder shall be free from material
defects in material and workmanship for a period of one (1) year from the
date of purchase. To reduce the risk of property damage due to water
leakage, this filter MUST be installed in accordance with the
manufacturer’s specifications and installations. This filter unit must be
replaced every 6 months, at the rated capacity, or sooner if reduced
water flow occurs. Protect form freezing. Failure to follow instructions
and operating specifications will void your warranty. Further,
manufacturer assumes no responsibility or liability for damages arising
out of misuse of the product.
Certified by IAPMO R&T against NSF/ANSI
42, 53, 372, 401, P473 & CSA B483.1 for
the reduction of chlorine taste and odor, Lead,
Cyst, Mercury, Asbestos, Pharmaceuticals
(such as Naproxen, Ibuprofen and Phenytoin),
BPA, PFOA/PFOS, Refer to Performance Data
Sheet for complete list of claims.
Not tested or certified by NSF International.
CHLORINE >97% 2.0 mg/L 1.0 mg/L
Asbestos
99.98% 189 MFL 99%
CYST
(Giardi; Cryptosporidium; Entamoeba; Toxoplasma)
>99.95%
MINIMUM 50,000/L
Cryptosporidium (see CYST)
>99.95% MINIMUM 50,000/L
IBUPROFEN
96.7% 0.432 mg/L <0.060 mg/L
LEAD (pH 6.5)
>99.3% 0.15 +/- 10% 0.010
LEAD (pH 8.5)
>99.3% 0.15 +/- 10% 0.010
% of Influent Max
Contaminant reduction Concentration Allowable
99.95% REDUCTION
REQUIREMENT
99.95% REDUCTION
REQUIREMENT
Mercury (pH 6.5)
74.9% 0.0059 0.002
Mercury (pH 8.5)
97.8% 0.0061 0.002
NAPROXEN
95.3% 0.130 mg/L <0.020 mg/L
PFOA
98.0% 0.0005 mg/L <0.00007 mg/L
PFOS
98.0% 0.001 mg/L <0.00007 mg/L
Phenytoin
94.7% 0.2173 mg/L <.030 mg/L
% of Influent Max
Contaminant reduction Concentration Allowable