Instructions

Documentation Testing Software (Status 28.09.2011)
HAZET
®
Torque-Tester 7901 E , 7902 E, 7903 E
Page 6 from 24
HAZET-WERK GmbH & Co. KG · Postfach 10 04 61 · D-42804 Remscheid · Germany
Telefon +49 (0) 21 91 / 7 92-0 · Telefax +49 (0) 21 91 / 7 92-375 · www.hazet.com · info@hazet.de
Testing equipment / serial interface
7. In the box <Port Configuration> you can modify the
connection conditions and transmission
specifications of your computer.
8. The settings <COM 1> up to <COM 4> indicate the
serial interface on the computer. Mark the COM
interface to which you connect the testing device.
9. The Port Configuration defines the value
transmission of the testing device to the PC and
always remains the same for the testing device
HAZET 7901 E, 7902 E and 7903 E.
Baud rate 9600
Parity N (none)
Data bits 8
Stop bits 1
Flow control none
10. To check the settings of the COM port on your PC,
select <Connections> in the device manager and
click on <Properties>.
Select <Connection conditions> on the register card
and enter the data from the above mentioned table.
11. The entries are saved by clicking on <OK>.
12. The settings for <Protocol> depend on the internal
cable configuration and can be selected by using
the scroll bar.
13. Click on <OK> to save the entries.
Note: Mandatory fields left unfilled will be red after