Step 11 Diagram A
Step 9: Run 3/8” tubing (not supplied) between the
screwdriver stop (installed in Step 5) and the
bottle filler’s supply inlet elbow in the
filter head (it may help to temporarily remove the
filter cartridgesee Step 9 Diagram).
Connect the wiring coming off of the filter
cartridge to the wiring coming out of the
circuit board enclosure (see Step 9 Diagram).
Step 10: Open the screwdriver stop wide open and check for leaks.
Close the hinged upper panel and provide power to the bottle
filler.
Step 11: Activate the bottle filler by placing a bottle or cup in front of the
sensor (see Step 11 Diagram A). If water does not dispense,
see the Troubleshooting Guide in the Owner’s Manual.
The pressure regulator may need to be adjusted to better
complement the input pressure at the installation site (see Step
11 Diagram B below). To do so, pull out the adjustment knob
and rotate as needed (clockwise from the front of the unit
decreases flow); push knob in when desired flow is achieved.
* Flow rate is factory set to the maximum flow rate for reduced
water consumption.
Step 12: Approximately five gallons of water must be run through the system after the unit is
installed in order to remove the loose carbon particles from the filter cartridge and any air
bubbles from the system (both of these are normal occurrences after a filter change).
Check the system for leaks. Place hex key in a secure location.
Step 9 Diagram (Back View)
Step 11 Diagram B