Instruction Manual

02/14   Model 1900  Page 2 of 7   
REQUIRED  TOOLS: Tubing  cutter,  electric  drill  with  standard  drill  bits,  #2  Phillips 
screwdriver, level. 
OTHER TOOLS (only needed for certain installation configurations – read installation 
procedure for details):  ABS cement, reciprocating saw or utility knife, hack saw or utility 
knife, slip joint pliers. 
LOCATION OF UNIT: The Model 1900 bottle filler is a wheelchair accessible drinking water 
bottle  filling  facility.  The  height  dimensions  shown  meet  current  ADA  requirements. When 
installing this  unit, local, state or  federal codes should  be adhered  to. If  height other  than 
shown is required, then dimensions must be adjusted accordingly. 
SUPPLY LINE: The minimum recommended line size is ¼ OD copper or plastic tubing with 
30-90 psi (2-6 ATM) pressure. Where sediment or mineral content is a problem, an inlet filter 
is recommended. 
PLUMBING  CONNECTIONS:  Inlet  is  1/4“  O.D.  push-in  type  fitting. Waste  outlet  is  1-1/4” 
O.D. pipe. 
MAINTENANCE:  Periodically  clean  the  strainer.  Refer  to  5874SS  Valve  Manual  for  more 
information. 
 INSTALLATION PROCEDURE 
GENERAL NOTES: 
1.  For all plastic push-in type fitting connections, only connect NSF-61 copper or 
plastic tubing. Stainless steel or glass tubing is not recommended. The 
following assembly instructions must be followed to ensure a watertight 
connection: 
a.  Cut tubing square and clean. 
b.  Mark from end of tube the length of insertion (See table below). 
c.  Push tube into the fitting until it bottoms out. 
d.  To remove, depress collet and pull tubing out. 
Tube Sizes 
O.D. 
Tolerance 
Insertion Depth 
1/4” 
±.005” 
11/16” 
3/8” 
±.005” 
3/4” 
1/2” 
±.005” 
7/8” 
Step 1:  Drain Setup 
This bottle filler uses a reversible drain basin (see installation drawing). 
  If the basin protrudes from the front of the unit, it will drain into the electric water 
cooler or drinking fountain below it. 
  If the basin protrudes from the back of the unit, it must be hard-plumbed to a 
waste line with a 1-1/4” O.D. slip joint connection (not supplied). 
Lay the drain basin seal (supplied) into the groove on the bottom surface of the bottle 
filler, and install the drain basin over it in the desired orientation, using the supplied 
#8 x 1/2" pan head screws (qty. 4). Be sure the seal stays seated in its groove. 
Front drainage setup: 
The drain will not empty into the bowl if the edge of the bowl is further than 6” 
away from the wall. In this case, install the drain extender (see “Alternate 
Configurations” in installation drawing), using ABS cement (not supplied) to 