Floor plate
European, national and local regulations must be observed in terms of the size and thickness of
a non-combustible floor covering the floor in front of the combustion chamber opening. Ask your
HWAM retailer for assistance. The combustion chamber opening is . cm wide.
Distance to combustible materials
If HWAM  is placed on a combustible floor, always mount it on a plinth whether or not the
floor is covered by a non-combustible material, such as a plate of glass or steel. The plinth is an
accessory. Contact your HWAM retailer for more information.
Min. distances - uninsulated flue gas pipe (drawing A)
HWAM 3110
HWAM 3120
HWAM 3130
. Recommended for brick wall
10 cm
.
For combustible back wall
12.5 cm
.
For combustible side wall
25.5 cm
.
To combustible wall, corner installation,
º
12.5 cm
.
Distance to furnishings in front
105 cm
. For combustible wall, side, in front of the stove 45 cm
Distance to mantel piece 45 cm
Min. distances - insulated flue gas pipe (drawing A)
HWAM 3110
HWAM 3120
HWAM 3130
. Recommended for brick wall
10 cm
.
For combustible back wall
7.5* cm
.
For combustible side wall
22 cm
.
To combustible wall, corner installation,
º
10 cm
.
Distance to furnishings in front
105 cm
. For combustible wall, side, in front of the stove 45 cm
Distance to mantel piece 45 cm
*We recommend  cm to facilitate service on HWAM
®
Autopilot™
For wall-mounting, HWAM  must be placed at least  cm above any combustible flooring.
This also applies to any floorboard placed on the floor.
Remember to pay attention to the applicable regulations concerning the required distance
between the wall and smoke pipe.
The distance to a brick wall is set to faciliate the servicing of the HWAM
®
Autopilot™. HWAM 
may be mounted with wall fittings only on a brick wall. The stove must be taken down when the
HWAM
®
Autopilot™ is to be serviced.
Please be aware that not all glass parts are heat-resistant. For this reason, a glass wall should
sometimes be treated as a flammable wall, in which case we ask you to contact your local chimney
sweep or glass producer to hear at what distance the stove should be kept from glass.
Requirements for chimney and smoke pipe
The height of the chimney must ensure sucient draught and prevent any smoke nuisance. As a
general rule, satisfactory draught conditions are achieved if the chimney is  m above the stove
and at least  cm above the ridge. If the chimney is placed at side walls, the top of the chimney