Table of contents Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-8 For UK - The Clean Air Act 1993 and Smoke Control Areas . . . . . . . . . . . . 9 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Firing manual - wood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Firing in general. . . . . . . . . . . . . . . . . . . . . . . . . . .
A. 1 1 45˚ 2 1 5 3 4 4 3 B. C.
E. F. 6 4 3 5 2 1 1 G1. G2.
H1.
H2.
K.
For UK - The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area. It is an offence to emit smoke from a chimney of a building, from a furnace or from any fixed boiler if located in a designated smoke control area.
Installation In general Congratulations on your new HWAM woodburning stove. We are pleased that you have chosen a HWAM woodburning stove and confident that it will give you much pleasure. To ensure optimum operation and safety, we recommend that the installation should be carried out by an authorised HWAM retailer or a fitter recommended by the retailer. For an overview of HWAM retailers, visit www.hwam.com under “Retailer locations”.
Floor plate European, national and local regulations must be observed in terms of the size and thickness of a non-combustible floor covering the floor in front of the combustion chamber opening. Ask your HWAM retailer for assistance. The combustion chamber opening is 34.0 cm wide. Distance to combustible materials If HWAM 3110 is placed on a combustible floor, always mount it on a plinth whether or not the floor is covered by a non-combustible material, such as a plate of glass or steel.
should always be higher than the ridge or the tallest point of the roof. Always be aware of any national and/or local regulations applying to thatched roofs and the location of the chimneys. The woodburning stove requires a minimum draught of 12 Pa (measured at EN 13240 measurement point). If measured just above the smoke flue socket, the chimney draught must be 18-20 Pa. The chimney must have a minimum clearing of Ø125 mm or Ø150 mm. The chimney must be provided with an easily accessible cleaning door.
• • • • • • Built-in pipe sleeve (12). Fits smoke flue. Wall rosette (13). Covers disruption to wall around pipe sleeve. Joint (14). Sealed with packing material. Smoke outlets (15) of the HWAM stove. Smoke flue regulating damper (16). Soot door (17). Fitting the loose parts Before the stove is installed, you must ensure that all loose parts are fitted correctly. Check that all insulation plates of the combustion chamber have been properly placed, i.e.
Firing manual - wood Your first heating session The lacquer will be fully hardened after the stove has been used, and the door and the ashpan should be opened very carefully as there will otherwise be a risk that the gaskets will stick to the lacquer. In addition the lacquer may initially give off an unpleasant odour, so make sure that the room is well ventilated. Tips about fuel Approved fuel types The wood burning stove is EN approved for combustion of wood only.
Turn the air control knob (1) clockwise to maximum. Place two pieces of wood (5-8 cm in diameter) horizontally in the bottom of the combustion compartment (corresponding to 1-2 kg). Place 5-8 pieces of kindling randomly on top. Place two firelighters between the top layer of kindling. Light up the fire-lighters and close the stove door. If condensation forms on the glass, keep the door ajar for a little while and close again.
Firing in general Rapid or fierce heat Rapid or fierce heat is obtained by burning many small pieces of wood. Maximum amounts of fuel: The maximum allowed amount of fuel per hour is: Wood: 1.46 kg If these limits are exceeded, the stove will no longer be covered by the factory guarantee, and it may also become damaged due to excessive heat, the glass may turn white, for example.. The stove has been approved for intermittent use.
Maintenance Cleaning Any maintenance of the stove should only be carried out when it is cold. Daily maintenance is limited to vacuum cleaning the stove externally, using the soft brush attachment. You can also dust the stove using a dry, soft cloth or brush. But remember, only when the stove is cold. Do not use water, spirit or any other kind of cleaner, as this will damage the lacquer. Once a year, the stove should be thoroughly serviced. The combustion chamber should be cleared of ashes and soot.
On a cold stove, the starting point of the feeler is controlled. The starting point on a cold stove is about 300 above horizontal. It should feel easy going and bouncy when you push it, no matter if the stove is cold or hot. By rising or falling temperatures it must not move at a bound. The damper plates must be dry and clean and slide together unhindered. Control bars and slide gates may have to be smeared with WD40 (never oil).
Operational problems Blackened glass • The wood is too damp. Only use wood stored for at least 12 months under cover and with a moisture level not exceeding 12-18% RH. • Faulty seal in door. Fit new seal. Smoke in the room when opening door • The grate in the chimney may be closed. Open the grate. • Insufficient chimney draft. See section on chimney or contact chimney sweep. • Soot door leaking or dislodged. Replace or refit. • Never open the door when there are still flames on the wood.
Product information on solid fuel local space heaters according to Comission regulation (EU) 2015/1185 HWAM 3110, HWAM 3120, HWAM 3130 Model 4,8 No - Direct heat output [kW] Indirect heating functionality Indirect heat output [kW] Type of heat output/room temperature control Two ore more manual stages, no temperature control Space heating performance at nominal heat output Seasonal space heating energy efficiency Fuel Preferred fuel [%] Yes Wood logs with moisture content 12-18 % 105 Emissions mg/m3 (