Owner manual
45
Trouble Shooting Air Spinmaster
Troubleshooting
Continued on next page.
Symptom Remedy
Actuate the Door Valve To Grip the
Pipe and nothing happens. (Con-
tinued)
The Spinner Rotates the Pipe
Slower Than Normal and Torque is
Insufcient.
37. Make sure that the lubricator is full and is me-
tering oil to the air motor. Do this by turning off
the main Power Pack valve, removing the main air
hose from the Power Pack to the Spinmaster and
turningthemainvalveonagain.Airshouldow
into the atmosphere with a very light oil mist that
would coat your hand. Now check the lubricator
drip adjustment. If the air lubricator is not func-
tioning correctly, rust could disable the air motor.
See Air Lubricator Adjustment Maintenance page
32 .
Make sure the Power Pack main air valve is fully
open. See Power Hook-Up pg.11.
Make sure that the air supply (volume and Pressure)
fromtherigsourceissufcienttogetmaximum
performance from the main Spinmaster motor
(250-300 scfm @100 psi).
Make sure that the air hose from the rig air supply
to the Spinmaster Power Pack is at least 1 1/4"
in size (1 1/2" air hose gives best performance
especially when the supply hose is longer than 25
foot) or the Spinmaster air motor will starve for
air. See Power Hook-up pg.11. In addition, any
ttingsthatareontheairsupplyhosetothePower
Packmusthaveequalorgreaterowcapacityas
the supply hose.
TheairlteronthePowerPackmaybeclogged.
See Changing Air Filter Element pg.33.
ThemuferontheSpinmasterairdrivemotorcould
berestrictingtheairowthroughthemotor.
Cleanorreplacethemufer.Forpartnumbersee
Drawings pg.48,52.
The gripping pressure output on the Power Pack
could be set too high. For proper adjustment, see
Adjusting Grip Pressure pg.34.
The drive rollers could be touching one another