Owner's manual

71
User Controls
OSD Menu Functions
IND100064-38
|---2---
Management Settings - Communication *Available in “Full Mode” only
The unit allows for remote control (adjust brightness for example) and/or accessing internal
information about the unit such as typenumber, serial number and more. To setup this feature, you
rst need to congure the Serial or Ethernet protocol properly to match your external equipment
specications. The contents of the submenus is listed below.
Settings as follows:
“RS232” = Sets the internal communication to standard RS-232 protocol.
“2-wire RS-485” = Sets the internal communication to RS-485 protocol
(Half duplex).
“4-wire RS485/422” = Sets the internal communication to RS-485/422 protocol
(Full duplex).
“Address RS” = Set the global unique channel/port ID for the unit, 16 ID’s available.
“IP Address” = IP can be found Automatically or you can set the IP address
manually (xxx.xxx.xxx.xxx) for Ethernet protocol by choosing
“Fixed IP”.
“Download” = Allows Factory Firmware upgrade for the unit via RS-232 Serial
Communication.
● Note: Default mode is “RS232” protocol.
A more detailed description of the SCOM (Serial/Ethernet Communication) can be found here:
http://www.hatteland-display.com/pdink/inb100018-4.php
Review also the “Pinout Assignments” chapter in this manual for additional help during preperation
and/or installation of external equipment intended to communicate with.