User Controls
OSD Menu Functions
IND100064-38
Management Settings
Allows you to adjust overall settings for interaction/communication for the unit, such as scaling, zoom,
timing of signals, adjust voltages for LED (which illuminate the front glass symbols), sensitivity for the touch
control, VGA lter and Serial/Ethernet communication and more. The contents of these submenus are listed
below.
|---2---
Management Settings - Graphic Scaling *Available in “Full Mode” only
Allow to scale the currently displayed full screen signal in various ways. The contents of the
submenus is listed below.
|--------3--------
Management Settings - Graphic Scaling - Scaling
All scaling will performed from center of active display area and outwards in all directions.
Settings as follows:
“Fill Screen” = Zoom current full screen signal to ll the entire active display
area. Aspect ratio is ignored, which means that picture may
appear distorted or stretched.
“Fill to Aspect Ratio” = Zoom current full screen signal to ll the entire active display
area and preserve the aspect ratio. This means that you may
notice black bars without any image information either on
top/bottom or left/right of the centered image.
“1:1” = Zoom current full screen signal to ll the entire active display
area as 1:1 native pixel resolution. Example; if the incoming
signal is a 800x600, on a 1600x1200 unit, the incoming
signal will be shown 50% less in size and centered on
screen. Aspect ratio is kept unchanged.
|--------3--------
Management Settings - Scaling - Zoom
All zooming will performed from center of active display area and outwards in all directions.
Settings as follows:
“Zoom” = Zoom the current full screen signal horizontally and vertically
in equal steps. Values from 0 to 100.
● Note: Values under or over 50, may cause blurry and unfocused imagery, since it overrides the