User Guide
Form No. DHLM-0105
9
INSTALLATION
Figure 8. Installation of Trac to an Outlet Box
Installing the Trac
(See Figure 8)
WARNING
To avoid any injury, turn the power supply OFF
to the mounting location before installing.
1. Punch out proper knockout holes in the ceiling
plate.
CAUTION
For safe and proper operation do not damage
the special, smooth plastic finish piece on metal
ceiling plate when determining location of
proper knock out holes.
2. Remove flat head screw(s) from back of live
end fitting and use them to fasten ceiling plate to
live end fitting.
3. Remove cover from live end fitting. Place Trac
with ceiling plate attached over outlet box and
mark the position of the Trac mounting holes on
ceiling or wall.
4. Drill mounting holes large enough for toggles
and install Trac with furnished toggle bolts. If
Trac is to be mounted on a solid surface, use #8
screws (not supplied) instead of toggle bolts.
5. Fasten ceiling plate to outlet box with two
screws. Pull wires from outlet box through open
hole in live end.
6. Cut and strip wires leads and fasten to screw
terminals in live end fitting. Push excess wires
back into outlet box and fasten ground wire to
green ground screw.
7. Replace cover on live end and tighten screw.
8. Slide lamp(s) with track mount into trac and
replace dead end fitting.
Outlet Box
Mounting Screws
Black Wire
L1 (Hot)
White Wire
(Neutral)
Green Wire
(Ground)
Green
Ground
Screw
Ceiling
Plate
Brass
Terminal
To Trac Mount: Drill holes in ceiling
or wall. Attach Trac with toggle bolts,
or screws if surface is solid material.
Nickel Plated
Terminal
Live End Cover
Ground Conductor Slide
Setscrew
Dead End Fitting
Flat Head Screws