Instruction Manual

Form No. EBOOSTERM-0321
15
English
INSTALLATION
Temperature/
Pressure Gauge
Temperature/
Pressure Gauge
Shock Absorber
for water hammer.
Discharge from T/P Valve.
Air gap must comply
with plumbing code.
3/4″ Gate or
Ball Valve
Blended Phosphate Water
Treatment System
Outlet
Drain Valve
3/4″
Union
Back
Pressure
Relief Valve
Inlet
Floor Drain
Outlet
Inlet
NOTE: Centerline of booster “T” fitting must
not extend closer than 102 mm (4) to the floor.
Pressure Reducing Valve
with High Pressure By-pass
(20 psi [138 kPa] flow
pressure maximum)
Temperature/Pressure
Relief Valve, 150 PSI/210°F
(1034 kPa/99°C)
Copper Water Inlet
from primary
water heater.
Copper Outlet
to Dishwasher.
Temperature/
Pressure Gauge
Temperature/
Pressure Gauge
Floor
Drain
Shock Absorber
for water hammer.
Copper Outlet
to Dishwasher.
Discharge from T/P Valve.
Air gap must comply
with plumbing code.
3/4″ Gate or
Ball Valve
Copper Water Inlet
from primary
water heater.
Blended Phosphate Water
Treatment System
Outlet
3/4
Union
Back
Pressure
Relief Valve
Inlet
Drain
Valve
Pressure Reducing Valve
with High Pressure By-pass
(20 psi [138 kPa] flow
pressure maximum)
Temperature/Pressure
Relief Valve, 150 PSI/210°F
(1034 kPa/99°C)
NOTE: Centerline of booster “T” fitting must
not extend closer than 102 mm (4) to the floor.
Two Imperial Models Connected in Series
Imperial “S” Series
Not supplied, but is available as an option/accessory.
Not supplied with booster heater.
Plumbing Connections
WARNING
Valves, gauges, and unions must be installed per diagram
to ensure proper operation, servicing, and warranty
coverage.