User manual

CFV 50c
35
Connectivity diagram
This diagram illustrates the situation regarding V System cameras and the connection requirements according to model.
All cables illustrated here are supplied.
CFV-50c
digital back
2000 FC / FCM
2003 FCW
201 F / 203 FE
205 TCC / FCC
Any view camera with
Hasselblad V System
adapter
1)
FlexBody
ArcBody
1)
Flash input
cable always
required
With C type lenses only
(C-mode setting)
May require a Battery
Adapter (3054668) at
certain extreme settings.
Optional accessory.
Phocus
remote control
(NOTE: only these cameras/
combinations can be con-
trolled from Phocus)
503 CW +
Winder CW
500 EL/ELM
500/553 ELX
555 ELD
+
Exposure cable 503 CW
required for Phocus control
of 503CW + Winder CW.
+
Battery Adapter (3054668)
required for portable use.
Optional accessory.
Exposure Cable EL required
for Phocus control of EL/ELM
and ELX use.
+
+
Battery Adapter (3054668)
required for portable use.
Optional accessory.
555 ELD
500 EL/ELM
500/553 ELX
500 C/CM
501 C/CM
503 CX/CXi/CW
SWC/M
903 SWC
905 SWC
Modified 202FA/203 FE / 205 TCC / 205 FCC
With F type lenses and CF type lenses at
F-mode setting
Cable free
operation
+
Battery Adapter (3054668)
required for portable use.
Optional accessory.
+
Battery Adapter (3054668)
required for portable use.
Optional accessory.
Some limitations regarding image quality apply
in some instances. See user manual for details.
1)
Note: Shift settings are not recommended on cameras with wide angle lenses
and a short lens to image plane distance. E.g. the ArcBody.