User manual
Table Of Contents
- Introduction
- Firmware Updates
- Disposal
- Restrictions and Recommendations
- GENERAL OVERVIEW
- Parts and Components – overview
- A6D Lens Range
- GETTING STARTED
- Mounting the lens
- Attaching the lens shield
- Attaching the adapter plate
- Power Connection
- Synchronous connections
- USB & link to Phocus or SDK based application
- Saving images to a memory card
- Attaching the USB cable Lock
- Settings
- Navigating the Menus
- Overview of Menus and Settings on Sensor Unit
- Touch Screen Navigation
- Button Navigation
- The Main Menu
- Add Favourite Functions to Main Menu Screen
- Remove Favourites from the Main Menu Screen
- Display Control Screen
- Settings on the Control Screen
- Camera Settings Menu
- Image Menu
- Quality Menu
- Video Settings Menu
- Quality Menu
- Live View Menu
- General Settings Menu
- Display Menu
- Storage Menu
- Date & Time Menu
- Power & Timeouts Menu
- Language Menu
- Service Menu
- About Menu
- Browsing images
- Preview Modes
- Standard Preview
- Browsing
- Zoom in and out
- 9 View Mode
- Folder View
- Card View
- Create New Folder
- CAMERA MAINTENANCE
- Cleaning Sensor Unit & IR Glass
- TECHNICAL APPENDIX
- A6D-100c Technical Specifications
- Lemo connector Signal Information
- Electrical Timings
- Coverage
- Coverage vs altitude
- GSD vs altitude
- Physical Dimensions
- Accessories
- FCC Class A Notice for A6D-100c
- FCC Caution
- Disclaimer
- Index
42
A6D User Manual
Characteristics Symbol Value Unit (DC)
H level output voltage (min) VOH 4.0 V
L level output voltage (max @ IOL) VOL 0.4 V
L level output current IOL 4.0 mA
H level input voltage (min) VIH 3.5 V
L level input voltage (max) VIH 1.5 V
Characteristics Symbol Value Unit (DC)
H level output voltage (max) VOH VSYS + V
Pull-up impedance R 10 Kohm
L level output voltage (max @ IOL) VOL 0.4 V
L level output current IOL 20.0 mA
Characteristics Symbol Value Unit (AC)
Rise time (max) tR 1.0 µs
Fall time (max) tF 1.0 µs
TRIG pulse width (min) tTRIG 10 ms
Expose start (min) tSTART 100 µs
Expose start (max) tSTART 1 ms
BUSY start (min) tBUSY 0 ms
BUSY start (max) tBUSY 200 ms
ACTIVE time (min) tACT 1000 ms
ACTIVE time (max) tACT ∞ s
Mid expose pulse width (typ) tMID 5 ms
VOLTAGE LIMIT
The electrical denition of signal type “CMOS” will be according to the limits
specied below:
The electrical denition of signal type “OC” will be according to the limits
specied below:
TRIG, -EXP and -BUSY timing relationship
Characteristics Symbol Value Unit (AC)
Maximum output voltage VSOH 5.25 V
Minimum output voltage VSOL 4.75 V
Characteristics Symbol Value Unit (AC)
Peak current consumption for VSYS+ ICC 40 mA
VOLTAGE LIMIT
The VSYS+ signal will conform to the following voltage requirements:
CURRENT LIMIT
The VSYS+ signal will conform to the following current requirements: