Repair Guide, Diagrams and Assembling Charts

Camera body 203FE - 205FCC - 205TCC
50
1
1
200
250
50
1
1
200
250
GRAM
Checks & Adjustments 3:5
VHAB Tool No. = ZZ88, Scale
Magnet hold capability
The magnet hold capability can be checked according to the diagram below. A suitable
scale, like the ZZ88, should be used. When measuring, it must indicate minimum 2 NCM
(200 gram) before each latching lever is released.
If indicating less then 2 NCM, the magnets should be cleaned and then rechecked. If still
less then 2 NCM after cleaning the Bottom mechanism plate, compl. (Part No. 105028)
must be changed. Magnets and latching levers are not available as spare parts due to
sensitive calibration procedures.
Magnet 2
Magnet 1
The magnets can be released from the
main circuit board when troubleshooting.
Use an external DC power supply and
apply 5 volt to the test points indicated.
Do not forget the grounding.
May 1997Revision 0