11. Technical Data
The Bari C.11,certiedincompliancewithDIN-EN 13240 : 2005-10/1 : 2008-06
and Art. 15 a B-VG (Austria),canonlybeoperatedwhenthereboxisclosed;more
than one device can be connected to the chimney. VKF-No.: 22674;
The following data applies to the chimney characteristics in accordance with EN
13384-1 / 2
Combustion Values Wood Briquette
Nominal Thermal Output 6 6 kW
CO content at 13% O2 80 79 mg/m³
Efciency 13 26 %
CO content at 13% O2 1104 882 mg/m³
WasteGasMassFlowRate 5,5 5,5 g/s
WasteGasOutletTemp. 320 320 ˚C
Min.SupplyPressureatNominalThermalOutput 12 12 Pa
Dependingontheinsulationofthebuilding,thenominalthermaloutputof6 kW indi-
cated on 20 - 80 m² (subject to change).
Dimensions: Height Width Depth
Stove 108/111,5/112cm 48cm 48cm
Fire box 43 cm 28 cm 30 cm
Weight Steel Ceramic Soapstone
141 kg 165 kg 205 kg
144 kg with ceramic
152 kg with soapstone
Heat retaining block + 81 kg
Flue pipe diameter: 15 cm
PipediameterofHaseventilationsystem* 10 cm
Front view Side view
Top view
Dimensions in cm
*Forseparateairsupplyinlow-energyhousesandinsufcientcombustionairsupply
in the room where the stove is installed
Connection area for the
inst. of Hase air system
below
Stove height: max. 112
Height for top installation: 105
Height for the inst. of Hase air
system: 9
24
Ø 35
6,5
Ø 48
Stove‘s angle of rotation:
180° · Can be stopped in
place and locked right/left in
15° gradients. Observe safety
distances to combustible or
ammablematerials!