User Manual

IS-22 Issue: 2 Date: 03.10.07 C/Note: 9874 Page 2 of 2
EXTRACTION PROCEDURE
To remove a contact from the moulding, select the correct Extraction Tool from the handle and
attach as before. Place this tool in the mating end of the socket and push firmly. Care should be
taken to keep the tool perpendicular to the mould face, or mould damage may occur.
Figure 1
Figure 2 Figure 3
(Correct contact position (Incorrect contact position
prior to final ‘click-in’) prior to final ‘click-in’)
Insertion Tool
Contact
Mouldin
g
Contact
Mouldin
g
Partially
Inserted
Contact
Mouldin
g
(back face)
Cable
Groove
Cable