Instruction Manual

24
Wiring Diagram
1. Connect the tractor Power / Communication (006-6650TM(E)) to the battery. The red power wire with the
50 amp fuse to the positive side (12 volt) of the battery. Connect the black ground wire to frame of tractor
or negative side.
a. The power harness must be connected to the battery! The unit will draw more amps than
convenience outlets can handle. Any modifications of the power harness will void systems warranty.
IF MODIFICATIONS ARE REQUIRED CONTACT HARVEST TEC FIRST!
b. This unit will not function on positive ground tractors.
2. Connect Pump Controller Harness (006-5650FC* or 006-5650F2M*) to DCP & Pump Controller (006-5672)
a. Connect Pump Harness (006-4660Z) and Flow Meter (006-4725A) to pump controller
3. Connect Moisture / Bale Rate Harness (006-7303H) to DCP.
4. Connect iPad Integration Control (030-6672C) to the Communication Harness (006-6650TM).
5. Connect the orange wires and attach the plug to the tractor’s ISOBUS port.
*Pump Control Harnesses 650 & 645 Models 006-5650FC | 651 Model 006-5650F2M
SYSTEM WIRING DIAGRAM
Dual Channel
Processor (DCP)
006-6671SS
iPad Integration Control
030-6672C
Data
Transfer
Moisture/Bale
Rate Harness
006-7303H(E)
Proximity Sensor (2X)
006-7303S
or 006-5650FC
Optional
Port
Star Wheel Assembly
030-4642 (2X)
End of Bale Sensor and Stroke Counter
006-7400
Power/Comm Harness on Baler
006-6650LS2
Power/Comm Harness on Tractor
006-6650TM(E)
Terminating Resistor
006-5650Z
Pump Controller Harness
006-5650F2M
Flow Meter
006-4725A
Pump Harness
006-4660Z
Pump Controller
006-5672
Connect Orange Wires
to Keyed Power
*Note: (E) indication is used
for International Dealers