Instruction Manual
7
Installation of Bale Sensor
The bale rate timer sensor is used to determine when the baler door is open. With this information the system
is able to change the tons/hour automatically (see Operating Instructions, Automatic Mode).
Locate the sensor (006-7400) and the sensor bracket (001-4648RB). On the right side of the baler find a
location 1”– 6” down from the hinge to mount the bracket. Check for clearance with hydraulic cylinders before
mounting the bracket. The bracket should be mounted to the front side of the hinge point, with the sensor
aligned over the back door.
Mark and drill two 1/4” (7mm) holes and install the bracket using two 5/16” x1/4” self-tapping bolts.
Install the sensor into the bracket and leave 1/4" (7mm) of clearance between the end of the sensor and the
door.
The harness will need to be routed towards the DCP. Secure with cable ties and take care to avoid pinch
points. The harness extension (006-7400EXT) may need to be used.
Hinge Point
001-4648RB
006-7400
View of the right side of
Back Door
Front of baler