Instruction Manual
6
Installation of Moisture Sensor Pads
1. If your baler is equipped with bale shaping pads, remove disc and use existing hole (may need to be drilled
larger, 3/4" (19mm) to install new moisture sensing discs.
2. If your baler is not equipped with bale shaping pads you will need to drill a hole in the chamber directly
behind and above the starting roll (Figure 1).
3. The mounting hole will be 3/4" (19mm) in diameter. Use a plastic pad (006-4641F) and place it into the
baler to use as a template. The bottom edge of the pad will be placed 1” (25mm) up from starting roll and
2” (51mm) from the back of the bale chamber (Figure 1).
4. Locate the 006-4641G (a) piece, this will need to be cut down to size. Use the already machined line in the
bushing to cut off the small piece shown above 006-4641G (b). Part 006-4641I may also need to be
trimmed to fit.
5. Depending on the baler the bolt may need to be trimmed for proper fit.
6. Tighten all of the hardware to 50 ft/lbs (68 N/m).
7. Make sure that the plastic pad is protecting all metal surfaces of the disc from touching baler.
8. Run the moisture wire harness (006-4640G2) from pump plate area to each disc securing with cable ties.
2” from back of
chamber (51mm)
1” from top of roll
(25mm)
Figure 1
006-4641G (a)
006-4641G (b)
006-4641I
006-4640G2
006-4641F